?> 50Hz 80kW 100kVA Deutz BF4M1013EC G1 Diesel Generator

50Hz 80kW 100kVA Diesel Generator with Deutz BF4M1013EC G1 Engine

50Hz 80kW 100kVA Diesel Generator with Deutz BF4M1013EC G1 Engine - Image 1
  • 50Hz 80kW 100kVA Diesel Generator with Deutz BF4M1013EC G1 Engine - Image 1
  • 50Hz 80kW 100kVA Diesel Generator with Deutz BF4M1013EC G1 Engine - Image 2
  • 50Hz 80kW 100kVA Diesel Generator with Deutz BF4M1013EC G1 Engine - Image 3
  • 50Hz 80kW 100kVA Diesel Generator with Deutz BF4M1013EC G1 Engine - Image 4

Short Description

GENLITEC POWER GPD100D5 / GPD100S5 powered by original DEUTZ diesel engine BF4M1013EC G1, with prime power 80kW/100kVA and standby power 88kW/110kVA.

  • ModelGPD100S5
  • Prime Power (PRP)80kW/100kVA
  • Standby Power (ESP)88kW/110kVA
  • EngineBF4M1013EC G1
  • Fuel Consumption (100%)24.2L/H
Share

Product Details

Product Tags

50Hz 80kW 100kVA Diesel Generator with DEUTZ BF4M1013EC G1 Diesel Engine

Introduction

The GENLITEC POWER GPD100D5 / GPD100S5 diesel generator set is designed to provide dependable power for commercial, industrial, and standby applications. Powered by a DEUTZ BF4M1013EC G1 diesel engine, the generator set is rated at 80kW/100kVA prime power and 88kW/110kVA standby power at 50Hz and 1500RPM.

With a 150L fuel tank, three-phase output, and multiple voltage configurations available, this generator set can be configured for a variety of power requirements. The GPD100D5 is the open type model, while the GPD100S5 features a sound-attenuated enclosure for outdoor and noise-sensitive applications.

Generator Set

Open Type Model GPD100D5
Silent Type Model GPD100S5
Frequency 50Hz
Phase & Wires 3 Phase, 4 Wires
Power Factor 0.8
Prime Power 80kW/100kVA
Standby Power 88kW/110kVA
Rated Voltage 220/380V; 230/400V; 240/415V (available configurations)
Rated Speed 1500 RPM
Fuel Tank Capacity 150L

Diesel Engine

Engine Model DEUTZ BF4M1013EC G1
Power Level G1
Power Standard LTP (Limited Time Power)
Cylinder Number 4
Cylinder Arrangement In-line
Engine Type 4-Stroke Diesel
Aspiration System Turbocharged, Charge Air Cooled (CAC)
Cooling Method Water Cooled
Fuel Injection System Single Injection Pumps
Bore x Stroke 108 x 130 mm
Compression Ratio 19:1
Rated Speed 1500 RPM
Displacement 4.76L
Gross Output (LTP / Standby) 102kW
Gross Output (PRP / Prime) 97kW
Gross Continuous Output 92kW
Fan Power Consumption 5.9kW
Engine Dry Weight (Without Cooling System) 526kg
Engine Weight (With Cooling System) 560kg
Oil Capacity 11L
Coolant Capacity (Engine) 7.4L
Coolant Capacity (Including Cooling Unit) 19.7L
Electrical System 24V DC
Starter Motor Power 6kW
Alternator Output 35A

Fuel Consumption

25% Load 6.7L/h
50% Load 12.2L/h
75% Load 18.0L/h
100% Load 24.2L/h

Fuel consumption figures are based on the DEUTZ BF4M1013EC G1 engine datasheet at 1500RPM. Actual generator set fuel consumption may vary with operating conditions, load profile, ambient conditions and configuration.

Alternator

Number of Phase 3
Rated Power 80kW/100kVA
Frequency 50Hz
Power Factor 0.8
Poles 4
Temperature Rise 125K
Terminals 6/12
Insulation Class H Class
Ambient Temperature 40°C
IP Rating IP23
Excitation System Self-Excited
Bearing Single Bearing
Coating Vacuum Impregnation
Voltage Regulator AVR
Coupling Flexible Disc

Control Panel

○ Emergency stop button ○ Main circuit breaker
○ Float battery charger ○ Manual/Auto start control panel
○ Fuel level meter ○ Controller power switch
○ Alarm buzzer ○ Remote monitoring interface

SOUND ATTENUATED ENCLOSURE

The GPD100S5 silent type generator set is equipped with a sound-attenuated enclosure designed to reduce operating noise and provide protection against outdoor weather conditions.

○ Sound-attenuated enclosure for reduced noise levels

○ Weatherproof design for outdoor installation

○ Internal exhaust silencer for effective noise reduction

○ Corrosion-resistant construction for long-term outdoor use

○ Service access doors for convenient maintenance

○ Suitable for commercial, industrial and standby power applications

Options

○ ATS for automatic start and stop when utility power fails or returns

○ Remote Monitoring System

○ Water-Jacket Heater

○ Larger-capacity fuel tank for extended runtime

○ Power sockets, including CEE or AUS standards

○ Customized voltage and control configurations

Applications

The GENLITEC POWER 80kW/100kVA diesel generator set is suitable for prime, standby and backup power applications, including:

○ Commercial and office buildings

○ Industrial facilities and workshops

○ Construction and job sites

○ Agricultural and rural facilities

○ Telecommunications and remote sites

○ Emergency and standby power systems

Why Choose GENLITEC POWER

GENLITEC POWER diesel generator sets combine dependable engine technology with practical configurations for a wide range of power requirements.

○ DEUTZ diesel engine for dependable power generation

○ Prime and standby power configurations for different operating requirements

○ Multiple voltage configurations available

○ Open and silent type configurations available

○ Suitable for commercial, industrial and backup power applications

○ Factory-direct supply with customized generator set solutions

For more information, please visit the GENLITEC POWER® Why Choose GENLITEC POWER page.

Warranty

GENLITEC POWER provides a standard warranty of 12 months or 1000 working hours, whichever comes first. For details, please refer to the GENLITEC POWER® Warranty Policy.

FAQ

Q: What is the rated power of the GPD100D5 / GPD100S5 generator set?
A: The generator set is rated at 80kW/100kVA prime power and 88kW/110kVA standby power.
Q: Which diesel engine powers the GPD100D5 / GPD100S5?
A: The generator set is specified with a DEUTZ BF4M1013EC G1, a four-cylinder, 4.76L, turbocharged and charge-air-cooled diesel engine.
Q: What is the fuel tank capacity?
A: The standard fuel tank capacity specified for this configuration is 150L.
Q: What is the fuel consumption of the BF4M1013EC G1 engine?
A: The engine datasheet lists approximate fuel consumption of 6.7L/h at 25% load, 12.2L/h at 50% load, 18.0L/h at 75% load and 24.2L/h at 100% load.
Q: What voltage configurations are available?
A: Available configurations may include 220/380V, 230/400V and 240/415V, subject to the selected alternator winding and connection.
Q: What is the difference between the open and silent type generator sets?
A: The GPD100D5 is the open type model, while the GPD100S5 is fitted with a sound-attenuated enclosure for reduced noise and weather protection.
Q: What is the warranty period for the GPD100D5 / GPD100S5?
A: GENLITEC POWER provides a standard warranty of 12 months or 1000 working hours, whichever comes first.

  • Previous: 500KVA Doosan Diesel Generator-50Hz
  • Next: 7m Manual 4x1000W Diesel Light Tower with Yanmar 3TNV76 Diesel Engine