P900-1 FG Wilson 900kVA Diesel Generator

P900-1 FG Wilson 900kVA Diesel Generator - Image 1

Short Description

FG Wilson P900-1 900kVA diesel generator with Perkins engine delivers reliable prime and standby power for data centers, healthcare, mining, and industry.

  • ModelFG Wilson P900-1
  • Prime Power800KVA/640KW
  • Standby Power892KVA/713.6KW
  • EnginePerkins 4006-23TAG3A
  • AlternatorFG Wilson FGL70030
  • ControllerDSE7420
  • MOQ1 Set

Product Details

Product Tags

Video

FG Wilson P900-1 900kVA diesel generator

The FG Wilson P900-1 is a high-performance diesel generator set designed to provide reliable prime and standby power for demanding industrial and commercial applications. Powered by a robust Perkins 4006-23TAG3A diesel engine and equipped with a FG Wilson FGL70030 alternator, this generator delivers dependable power output, excellent durability and stable performance for continuous and emergency power requirements.

The P900-1 generator set provides 800kVA/640kW prime power and 892kVA/713.6kW standby power at 50Hz, with 380/400/415V three-phase output. It features a DSE7420 digital controller, original ABB main circuit breaker, engine-driven radiator and a large 1494-litre fuel tank. The sound-attenuated enclosure and heavy-duty construction make the FG Wilson P900-1 suitable for industrial plants, construction projects, data centres, infrastructure facilities and other applications requiring dependable high-capacity power generation.

Generator Set

Model FG Wilson P900-1
Frequency 50Hz
Prime Power 800kVA / 640kW
Standby Power 892kVA / 713.6kW
Voltage 380/400/415V
Phase 3-Phase, 4-Wire
Power Factor 0.8
Engine Perkins 4006-23TAG3A
Alternator FG Wilson FGL70030
Control Panel DSE7420
Fuel Tank Capacity 1494 Litres

Diesel Engine

Engine Model Perkins 4006-23TAG3A
Number of Cylinders 6
Bore x Stroke 160 x 190mm
Induction Turbocharged Air-to-Air Charge Cooled
Governor Type Electronic
Displacement 22.9L
Starting Voltage 24V DC

Alternator

Alternator Model FG Wilson FGL70030
Voltage 380/400/415V
Frequency 50Hz
Phase 3-Phase, 4-Wire
Power Factor 0.8
Insulation Class H

Fuel Consumption

Load Fuel Consumption
110% Load 195.5L/H
100% Load 172.9L/H
75% Load 130.7L/H
50% Load 92.7L/H

Control Panel

○ DSE7420 digital controller

○ Original ABB main circuit breaker

○ Emergency stop button

○ Complete engine alarm and protection system

Standard Configuration

○ Original radiator with engine-driven cooling fan

○ Diesel engine and alternator mounted on a heavy-duty base frame

○ Anti-vibration mounting system

○ 24V DC electric starting system

○ Maintenance-free lead-acid batteries

○ Float battery charger

○ Industrial silencer with flexible connection and elbow

Sound Attenuated Enclosure

○ Fully weatherproof sound-attenuated enclosure with internal exhaust silencer

○ Highly corrosion-resistant construction for demanding outdoor environments

Applications

The FG Wilson P900-1 diesel generator is designed for reliable high-capacity power generation in demanding commercial, industrial and infrastructure environments. Typical applications include:

○ Industrial plants

○ Construction projects

○ Mining operations

○ Data centres and telecommunications facilities

○ Infrastructure and utility projects

○ Commercial buildings

○ Emergency and standby power applications

Why Choose FG Wilson P900-1

The FG Wilson P900-1 combines a proven Perkins diesel engine, FG Wilson alternator and reliable control system to provide stable and dependable power for demanding applications. Its high-capacity fuel tank, robust construction and weatherproof enclosure make it suitable for long-duration operation in industrial and commercial environments.

○ Proven Perkins 4006-23TAG3A diesel engine

○ FG Wilson FGL70030 alternator

○ 800kVA prime power and 892kVA standby power

○ Original ABB main circuit breaker

○ DSE7420 digital control system

○ 1494-litre fuel tank for extended operation

Warranty

GENLITEC POWER® provides a warranty of 12 months or 1,000 working hours, whichever comes first. For complete warranty terms, please refer to the following policy:

GENLITEC POWER® Warranty Policy

Frequently Asked Questions

What is the prime power rating of the FG Wilson P900-1?

The FG Wilson P900-1 provides 800kVA / 640kW prime power at 50Hz.

What is the standby power rating of the P900-1?

The generator provides 892kVA / 713.6kW standby power at 50Hz.

What diesel engine is used in the FG Wilson P900-1?

The P900-1 is powered by a Perkins 4006-23TAG3A six-cylinder diesel engine with a 22.9-litre displacement and electronic governor.

What alternator is fitted to the P900-1?

The generator is equipped with a FG Wilson FGL70030 alternator for stable three-phase power output.

What control panel does the FG Wilson P900-1 use?

The P900-1 is equipped with a DSE7420 digital generator controller and an ABB main circuit breaker.

What is the fuel tank capacity of the P900-1?

The FG Wilson P900-1 is equipped with a 1494-litre fuel tank for extended operating periods.


  • Previous: 50Hz 22kW 28kVA Cummins 4B3.9-G2 Diesel Generator
  • Next: P850-1 FG Wilson 850kVA Diesel Generator

  • Related Products