GENLITEC POWER GPD450D5-II / GPD450S5-II diesel generator powered by Deutz BF8M1015C-LA G2, with prime power 360kW/450kVA and standby power 400kW/500kVA.

  • ModelGPD450S5-II
  • Prime Power (PRP)360kW/450kVA
  • Standby Power (ESP)400kW/500kVA
  • EngineBF8M1015C-LA G2
  • Fuel Consumption (100%)94L/H
Share

Product Details

Product Tags

50Hz 360kW 450kVA DEUTZ BF8M1015C-LA G2 Diesel Generator Set

Introduction

The GENLITEC POWER GPD450D5-II / GPD450S5-II is a 450kVA DEUTZ diesel generator set designed to provide reliable prime, standby and backup power for industrial, commercial and infrastructure applications. Powered by the DEUTZ BF8M1015C-LA G2 diesel engine, this 50Hz generator operates at 1500RPM and delivers 360kW/450kVA prime power and 400kW/500kVA standby power. Equipped with a 680L fuel tank and available in three-phase, four-wire voltage configurations of 220/380V, 230/400V and 240/415V, the GPD450 series offers flexible power solutions for different electrical requirements. The GPD450D5-II open-type diesel generator provides convenient access for maintenance, while the GPD450S5-II silent diesel generator features a sound-attenuated enclosure for noise-sensitive environments and outdoor installations. These DEUTZ-powered generator sets are suitable for factories, commercial buildings, construction sites, agricultural facilities, telecommunications infrastructure and emergency backup power systems.

Generator Set

Open Type Model GPD450D5-II
Silent Type Model GPD450S5-II
Engine Brand DEUTZ
Frequency 50Hz
Phase & Wires 3 Phase, 4 Wires
Power Factor 0.8
Prime Power 360kW/450kVA
Standby Power 400kW/500kVA
Rated Voltage 220/380V; 230/400V; 240/415V
Rated Speed 1500 RPM
Fuel Tank Capacity 680L

Diesel Engine

Engine Brand DEUTZ
Engine Model BF8M1015C-LA G2
Cylinder Number 8
Cylinder Arrangement V-Type, 90°
Engine Type 4-Stroke Diesel
Aspiration System Turbocharged with Charge Air Cooling
Cooling Method Water Cooled
Governor Type Electronic Governor
Fuel Injection System Direct Injection
Bore x Stroke 132 x 145 mm
Compression Ratio 16.5:1
Rated Speed 1500 RPM
Displacement 15.874L
Prime Power (Engine) 403kW
Standby Power (Engine) 440kW
Oil Capacity 48L
Coolant Capacity 87L (Complete cooling system)
Electric Starting System DC 24V

Fuel Consumption

100% Prime Load 94L/H
75% Prime Load 71L/H
50% Prime Load 47L/H
25% Prime Load N/A

Alternator

Number of Phase 3
Rated Power 360kW/450kVA
Frequency 50Hz
Power Factor 0.8
Poles 4
Temperature Rise 125K
Terminals 6/12
Insulation Class H Class
Ambient Temperature 40℃
IP Rating IP23
Excitation System Self-Excited
Bearing Single Bearing
Coating Vacuum Impregnation
Voltage Regulator AVR
Coupling Flexible Disc

Control Panel

○ Emergency stop button ○ Main circuit breaker
○ Float battery charger ○ Manual/Auto start control panel
○ Fuel level meter ○ Controller power switch
○ Alarm buzzer ○ Remote monitoring interface

SOUND ATTENUATED ENCLOSURE

The GPD450S5-II silent type generator set is equipped with a sound-attenuated enclosure designed to reduce operating noise and provide weather protection for outdoor applications.

○ Sound-attenuated enclosure for reduced noise levels

○ Weatherproof design for outdoor installation

○ Internal exhaust silencer for effective noise reduction

○ Corrosion-resistant construction for long-term outdoor use

○ Service access doors for convenient maintenance

○ Suitable for commercial, industrial and standby power applications

Options

○ ATS for automatic start and stop when utility power fails or returns

○ Remote Monitoring System

○ Water-Jacket Heater

○ Synchronization system

Applications

The GENLITEC POWER 360kW/450kVA DEUTZ diesel generator set is suitable for a wide range of prime, standby and backup power applications, including:

○ Commercial and office buildings

○ Industrial facilities

○ Construction and job sites

○ Agricultural and rural facilities

○ Telecommunication and remote sites

○ Emergency and standby power systems

Why Choose GENLITEC POWER

GENLITEC POWER diesel generator sets are designed to provide dependable power, practical configuration and reliable performance for a wide range of applications.

○ DEUTZ diesel engine for reliable power generation

○ Prime and standby power configurations for different operating requirements

○ Multiple voltage configurations available

○ Open and silent type configurations available

○ Suitable for commercial, industrial and backup power applications

○ Factory-direct supply with customized generator set solutions

For more information, please visit the GENLITEC POWER® Why Choose GENLITEC POWER page.

Warranty

GENLITEC POWER provides a standard warranty of 12 months or 1000 working hours, whichever comes first. For details, please refer to the GENLITEC POWER® Warranty Policy.

FAQ

Q: What is the rated power of the GPD450D5-II / GPD450S5-II generator set?
A: The generator set delivers 360kW/450kVA prime power and 400kW/500kVA standby power.
Q: Which diesel engine powers the GPD450D5-II / GPD450S5-II?
A: The generator set is powered by a DEUTZ BF8M1015C-LA G2 eight-cylinder, 15.874L V-type diesel engine featuring turbocharging, charge air cooling and electronic governing.
Q: What voltage configurations are available?
A: Available rated voltage configurations include 220/380V, 230/400V and 240/415V.
Q: What is the difference between the open and silent type generator sets?
A: The GPD450D5-II is the open type model, while the GPD450S5-II features a sound-attenuated enclosure for applications where noise reduction and weather protection are required.
Q: What is the frequency and rated speed of the generator set?
A: The generator set operates at 50Hz with a rated speed of 1500 RPM.
Q: What is the fuel tank capacity?
A: The GPD450 series is specified with a 680L fuel tank.
Q: Is remote monitoring available for the generator set?
A: Yes. A Remote Monitoring System is available as an optional configuration for remote status monitoring and generator set management.
Q: What is the warranty period for the GPD450D5-II / GPD450S5-II?
A: GENLITEC POWER provides a standard warranty of 12 months or 1000 working hours, whichever comes first.