50Hz 250kW 313kVA Diesel Generator with Cummins NTA855-G1B Engine
Short Description
GENLITEC POWER GPC313D5-II/GPC313S5-II delivers 250kW/313kVA prime power with a Cummins NTA855-G1B engine for industrial, commercial and backup power.
- ModelGPC313D5-II | GPC313S5-II
- Frequency50Hz
- Prime Power250KW/313KVA
- Standby Power275KW/344KVA
- EngineCummins NTA855-G1B
- AlternatorStamford/Leroy Somer/Genlitec Power
- Fuel Consumption (100% Load)69.5L/H
- MOQ1 Set
Product Details
Product Tags
Video
Introduction
The GENLITEC POWER® GPC313D5-II open type and GPC313S5-II silent type diesel generator sets deliver 250kW/313kVA prime power and 275kW/344kVA standby power. Powered by an original CUMMINS 6LTAA9.5-G1 six-cylinder diesel engine and matched with a high-quality brushless copper alternator, these generator sets are designed to provide stable power, dependable operation and long service life for demanding commercial, industrial, construction, mining, infrastructure and backup power applications.
One of the key advantages of the GPC313D5-II and GPC313S5-II is the use of a proven CUMMINS 6LTAA9.5-G1 engine. With a 9.5L displacement, 290kW rated power, 320kW standby power, turbocharged air cooling and electronic governing, the engine provides a substantial power reserve above the generator set's 250kW prime output. This configuration helps the genset handle demanding loads while maintaining reliable performance during continuous operation.
The generator set is equipped with a 250kW/313kVA alternator featuring H Class insulation, 125K temperature rise, IP23 protection, vacuum impregnation and an AVR voltage regulation system. These component specifications are selected to provide reliable voltage regulation, stable power output and durability for professional power generation applications.
Designed for 50Hz operation at 1500 RPM, the generator set provides three-phase, four-wire output with flexible voltage configurations including 220/380V, 230/400V and 240/415V. A 500L fuel tank provides extended operating capability, while ATS, water-jacket heater, synchronization and remote monitoring systems can be supplied according to project requirements.
The GPC313D5-II open type is suitable for generator rooms, industrial facilities and installations where ventilation, service access and easy maintenance are priorities. The GPC313S5-II silent type features a weatherproof sound-attenuated enclosure with an internal exhaust silencer, making it suitable for outdoor installations, commercial sites and applications where reduced operating noise and environmental protection are important.
Generator Set
| Open Type Model | GPC313D5-II |
| Silent Type Model | GPC313S5-II |
| Prime Power | 250kW/313kVA |
| Standby Power | 275kW/344kVA |
| Phase & Wire | 3 Phase, 4 Wires |
| Power Factor | 0.8 |
| Frequency | 50Hz |
| Rated Voltage | 220/380V, 230/400V, 240/415V |
| Fuel Tank Capacity | 500L |
Diesel Engine
| Engine Model | CUMMINS NTA855-G1B |
| Cylinder Number | 6 |
| Aspiration System | Turbocharged & Aftercooled |
| Cooling Method | Water Cooled |
| Governor Type | Electronic |
| Bore x Stroke | 140 x 152 mm |
| Compression Ratio | 14:1 |
| Rated Speed | 1500 RPM |
| Displacement | 9.5L |
| Rated Power | 284KW |
| Standby Power | 321KW |
| Fuel System | Cummins PT Pump |
| Oil Capacity | 38.6L |
| Coolant Capacity | 60.6L |
| Electric Starting System | DC 24V |
Fuel Consumption
| 100% Prime Load | 69.5L/H |
| 75% Prime Load | 53.1L/H |
| 50% Prime Load | 37.6L/H |
| 25% Prime Load | 21.3L/H |
Alternator
| Number of Phase | 3 |
| Rated Power | 250KW/313KVA |
| Frequency | 50Hz |
| Power Factor | 0.8 |
| Poles | 4 |
| Temperature Rise | 125K |
| Terminals |
6 (12 leads for option) |
| Insulation Class | H Class |
| Ambient Temperature | 40℃ |
| IP Rating | IP23 |
| Excitation System | Self-Excited |
| Bearing | Single Bearing |
| Coating | Vacuum Impregnation |
| Voltage Regulator | A.V.R |
| Coupling | Flexible Disc |
Control Panel
| ○ Emergency stop button | ○ Main circuit breaker |
| ○ Float battery charger | ○ Manual/Auto start control panel |
| ○ Fuel level meter | ○ Controller power switch |
| ○ Alarm buzzer |
Sound Attenuated Enclosure
○ Weatherproof sound-attenuated enclosure with internal exhaust silencer
○ Corrosion-resistant construction for outdoor installation
○ Available for GPC313S5-II silent type generator set
Options
○ ATS for automatic start and stop when utility power fails or returns
○ Double-axle trailer
○ 12-hour fuel tank
○ 24-hour fuel tank
○ Water-jacket heater
○ Other heaters
○ AREM & PMG
○ Synchronization System
○ Remote & Monitoring System
Applications
The GENLITEC POWER 250kW/313kVA diesel generator set is suitable for a wide range of prime, standby and backup power applications, including:
○ Commercial buildings and office complexes
○ Industrial facilities and manufacturing plants
○ Construction sites and infrastructure projects
○ Mining and heavy-duty applications
○ Telecommunication and remote facilities
○ Data centers and critical power systems
○ Emergency and standby power applications
Why Choose GENLITEC POWER
GENLITEC POWER focuses on the quality of the complete generator package rather than simply selecting an engine and alternator based on rated output. For professional power applications, the performance and reliability of a genset depend on the quality and compatibility of its major components, including the diesel engine, alternator, control system, cooling system and fuel system. The GPC313D5-II and GPC313S5-II are configured with carefully selected components to provide dependable performance and long-term value.
○ Original CUMMINS NTA855-G1B diesel engine for proven power and reliability
○ 290kW rated engine power provides a substantial power reserve for the 250kW prime output
○ High-quality brushless copper alternator matched to the 250kW/313kVA generator output
○ H Class insulation, 125K temperature rise and vacuum impregnation for demanding applications
○ AVR voltage regulation for stable and reliable electrical output
○ 500L fuel tank for extended operating periods
○ Open type and silent type configurations for different installation environments
○ ATS, synchronization, remote monitoring and heater options for project-specific requirements
○ Professional factory assembly, testing and quality control before shipment
○ International export experience and technical support for different markets and applications
For more information, please visit the GENLITEC POWER® Why Choose GENLITEC POWER page.
Warranty
GENLITEC POWER provides a standard warranty of 12 months or 1000 working hours, whichever comes first. For details, please refer to the GENLITEC POWER® Warranty Policy.