50Hz 360kW 450kVA Diesel Generator with Cummins KTA19-G3 Engine

50Hz 360kW 450kVA Diesel Generator with Cummins KTA19-G3 Engine - Image 1
  • 50Hz 360kW 450kVA Diesel Generator with Cummins KTA19-G3 Engine - Image 1
  • 50Hz 360kW 450kVA Diesel Generator with Cummins KTA19-G3 Engine - Image 2
  • 50Hz 360kW 450kVA Diesel Generator with Cummins KTA19-G3 Engine - Image 3
  • 50Hz 360kW 450kVA Diesel Generator with Cummins KTA19-G3 Engine - Image 4

Short Description

GENLITEC POWER® GPC450D5-II/GPC450S5-II diesel generator set with original CUMMINS KTA19-G3, 360KW/450KVA prime and 400KW/500KVA standby power.

  • ModelGPC450D5-II | GPC450S5-II
  • Frequencyf50Hz
  • Prime Power360KW/450KVA
  • Standby Power400KW/500KVA
  • EngineCummins KTA19-G3
  • AlternatorStamford/Leroy Somer/Genlitec Power
  • Fuel Consumption (100% Load)82kg/H
  • MOQ1 Set

Product Details

Product Tags

Video

450kVA Cummins KTA19-G3 diesel generator set GPC450D5-II open type and GPC450S5-II silent type

Introduction

The GENLITEC POWER® GPC450D5-II and GPC450S5-II are 450kVA Cummins diesel generator sets designed to provide reliable three-phase power for industrial, commercial, construction, mining, infrastructure and standby power applications. The generator sets are rated at 360kW/450kVA for prime power and 400kW/500kVA for standby power at 50Hz, with 1500 RPM operation.

Powered by the Cummins KTA19-G3 six-cylinder, 19-liter diesel engine, the GPC450 series combines high engine capacity with a 360kW/450kVA alternator output. The Cummins KTA19-G3 uses a turbocharged and aftercooled configuration, Cummins PT fuel system, direct injection and electronic governor. At 50Hz and 1500 RPM, the engine provides approximately 403kW prime output and 448kW standby output, providing suitable engine capacity for the rated generator set output.

The GPC450 generator set is available in both open and silent configurations. The GPC450D5-II open type is suitable for generator rooms and installations where easy maintenance and ventilation are required, while the GPC450S5-II silent type features a weatherproof sound-attenuated enclosure for outdoor and noise-sensitive applications. A 680L fuel tank is provided for extended operating periods, while ATS, synchronization, remote monitoring and other options are available for different project requirements.

Generator Set

Open Type Model GPC450D5-II
Silent Type Model GPC450S5-II
Prime Power 360KW/450KVA
Standby Power 400KW/500KVA
Phase & Wire 3 Phase, 4 Wires
Power Factor 0.8
Frequency 50Hz
Voltage 220/380V, 230/400V, 240/415V
Fuel Tank Capacity 680L

Diesel Engine

Engine Model CUMMINS KTA19-G3
Cylinder Number 6
Aspiration System Turbocharged, Aftercooled
Cooling Method Water Cooled
Governor Type Electronic
Bore x Stroke 159 x 159 mm
Compression Ratio 13.9:1
Rated Speed 1500 RPM
Displacement 19L
Prime Power 403KW
Standby Power 448KW
Fuel System Cummins PT, Direct Injection
Electric Starting System DC 24V

Fuel Consumption

100% Prime Load 82kg/H
75% Prime Load 62kg/H
50% Prime Load 43kg/H
25% Prime Load 26kg/H

Alternator

Number of Phase 3
Rated Power 360KW/450KVA
Frequency 50Hz
Power Factor 0.8
Poles 4
Temperature Rise 125K
Terminals 12
Insulation Class H Class
Ambient Temperature 40℃
IP Rating IP23
Excitation System Self-Excited
Bearing Single Bearing
Coating Vacuum Impregnation
Voltage Regulator A.V.R
Coupling Flexible Disc

Control Panel

○ Emergency stop button ○ Main circuit breaker
○ Float battery charger ○ Manual/Auto start control panel
○ Fuel level meter ○ Controller power switch
○ Alarm buzzer

Sound Attenuated Enclosure

○ Weatherproof sound-attenuated enclosure with internal exhaust silencer

○ Corrosion-resistant construction for outdoor installation

○ Available for GPC450S5-II silent type generator set

Options

○ ATS for automatic start and stop when utility power fails or returns

○ 12-hour fuel tank

○ 24-hour fuel tank

○ Water-jacket heater

○ Other heaters

○ AREM & PMG

○ Synchronization System

○ Remote & Monitoring System

Applications

The GENLITEC POWER 360kW/450kVA Cummins diesel generator set is suitable for prime and standby power applications where stable and dependable power is required, including:

○ Commercial buildings and office complexes

○ Industrial facilities and manufacturing plants

○ Construction sites and infrastructure projects

○ Mining and heavy-duty applications

○ Telecommunication and remote facilities

○ Data centers and critical power systems

○ Emergency and standby power applications

Why Choose GENLITEC POWER

GENLITEC POWER combines established engine technology, carefully selected generator components and professional assembly to provide reliable diesel generator sets for demanding power applications. The GPC450 series uses the Cummins KTA19-G3 engine and is configured to deliver 360kW/450kVA prime power with suitable engine reserve capacity.

○ Genuine Cummins KTA19-G3 diesel engine configuration

○ 360kW/450kVA prime power and 400kW/500kVA standby power

○ 19L six-cylinder turbocharged and aftercooled diesel engine

○ Cummins PT fuel system and direct injection

○ Approximately 403kW prime and 448kW standby engine output at 50Hz

○ 680L fuel tank for extended operating periods

○ High-quality alternator with H Class insulation and IP23 protection

○ Open and silent configurations for different installation requirements

○ ATS, synchronization and remote monitoring options available

○ Professional manufacturing, testing and international export experience

For more information, please visit the GENLITEC POWER® Why Choose GENLITEC POWER page.

Warranty

GENLITEC POWER provides a standard warranty of 12 months or 1000 working hours, whichever comes first. For details, please refer to the GENLITEC POWER® Warranty Policy.

Frequently Asked Questions

Q: What is the rated power of the GPC450 Cummins diesel generator set?
A: The GPC450D5-II open type and GPC450S5-II silent type are rated at 360kW/450kVA for prime power and 400kW/500kVA for standby power at 50Hz.
Q: Which Cummins engine is used in the 450kVA generator?
A: The GPC450 series is powered by the Cummins KTA19-G3, a six-cylinder 19L diesel engine with turbocharged and aftercooled technology, Cummins PT fuel system, direct injection, electronic governor and 1500 RPM rated speed.
Q: What is the Cummins KTA19-G3 engine output at 50Hz?
A: The Cummins KTA19-G3 provides approximately 403kW prime engine output and 448kW standby engine output at 1500 RPM and 50Hz. These are engine output ratings, while the GENLITEC POWER generator set is rated at 360kW/450kVA prime and 400kW/500kVA standby.
Q: What is the fuel tank capacity and fuel consumption?
A: The standard GPC450 configuration is equipped with a 680L fuel tank. Fuel consumption is approximately 97L/H at 100% prime load, 73L/H at 75% load, 51L/H at 50% load and 30L/H at 25% load.
Q: What voltage and frequency can the GPC450 generator provide?
A: The standard configuration is 50Hz, three-phase, four-wire output. Available voltage configurations include 220/380V, 230/400V and 240/415V, depending on the selected alternator configuration and project requirements.
Q: What is the difference between the GPC450D5-II and GPC450S5-II?
A: Both models use the same Cummins KTA19-G3 engine and generator rating. The GPC450D5-II is an open type generator set designed mainly for generator rooms and installations with suitable ventilation, while the GPC450S5-II uses a weatherproof sound-attenuated enclosure for outdoor and noise-sensitive applications.
Q: Is the GPC450 suitable for prime power applications?
A: Yes. The GPC450 series is rated at 360kW/450kVA prime power and is suitable for long-duration power applications when operated within the specified load profile, environmental conditions and maintenance requirements.
Q: Can the GPC450 be configured for automatic operation or parallel operation?
A: Yes. ATS, automatic start and stop, synchronization and paralleling systems, remote monitoring, water-jacket heaters and other options can be configured according to the project requirements.
Q: Where can the 450kVA Cummins generator be used?
A: The GPC450 series is suitable for factories, commercial buildings, construction sites, mining projects, infrastructure, telecommunications, data centers and other applications requiring reliable prime or standby power.
Q: What warranty is provided for the GPC450 series?
A: The standard warranty is 12 months or 1000 working hours, whichever comes first.

  • Previous: 50Hz 380kW 475kVA Diesel Generator with Cummins QSZ13-G3 Engine
  • Next: 50Hz 360kW 450kVA Diesel Generator with Cummins QSZ13-G5 Engine