50Hz 360kW 450kVA Diesel Generator with Cummins KTA19-G3 Engine
Short Description
GENLITEC POWER® GPC450D5-II/GPC450S5-II diesel generator set with original CUMMINS KTA19-G3, 360KW/450KVA prime and 400KW/500KVA standby power.
- ModelGPC450D5-II | GPC450S5-II
- Frequencyf50Hz
- Prime Power360KW/450KVA
- Standby Power400KW/500KVA
- EngineCummins KTA19-G3
- AlternatorStamford/Leroy Somer/Genlitec Power
- Fuel Consumption (100% Load)82kg/H
- MOQ1 Set
Product Details
Product Tags
Video
Introduction
The GENLITEC POWER® GPC450D5-II and GPC450S5-II are 450kVA Cummins diesel generator sets designed to provide reliable three-phase power for industrial, commercial, construction, mining, infrastructure and standby power applications. The generator sets are rated at 360kW/450kVA for prime power and 400kW/500kVA for standby power at 50Hz, with 1500 RPM operation.
Powered by the Cummins KTA19-G3 six-cylinder, 19-liter diesel engine, the GPC450 series combines high engine capacity with a 360kW/450kVA alternator output. The Cummins KTA19-G3 uses a turbocharged and aftercooled configuration, Cummins PT fuel system, direct injection and electronic governor. At 50Hz and 1500 RPM, the engine provides approximately 403kW prime output and 448kW standby output, providing suitable engine capacity for the rated generator set output.
The GPC450 generator set is available in both open and silent configurations. The GPC450D5-II open type is suitable for generator rooms and installations where easy maintenance and ventilation are required, while the GPC450S5-II silent type features a weatherproof sound-attenuated enclosure for outdoor and noise-sensitive applications. A 680L fuel tank is provided for extended operating periods, while ATS, synchronization, remote monitoring and other options are available for different project requirements.
Generator Set
| Open Type Model | GPC450D5-II |
| Silent Type Model | GPC450S5-II |
| Prime Power | 360KW/450KVA |
| Standby Power | 400KW/500KVA |
| Phase & Wire | 3 Phase, 4 Wires |
| Power Factor | 0.8 |
| Frequency | 50Hz |
| Voltage | 220/380V, 230/400V, 240/415V |
| Fuel Tank Capacity | 680L |
Diesel Engine
| Engine Model | CUMMINS KTA19-G3 |
| Cylinder Number | 6 |
| Aspiration System | Turbocharged, Aftercooled |
| Cooling Method | Water Cooled |
| Governor Type | Electronic |
| Bore x Stroke | 159 x 159 mm |
| Compression Ratio | 13.9:1 |
| Rated Speed | 1500 RPM |
| Displacement | 19L |
| Prime Power | 403KW |
| Standby Power | 448KW |
| Fuel System | Cummins PT, Direct Injection |
| Electric Starting System | DC 24V |
Fuel Consumption
| 100% Prime Load | 82kg/H |
| 75% Prime Load | 62kg/H |
| 50% Prime Load | 43kg/H |
| 25% Prime Load | 26kg/H |
Alternator
| Number of Phase | 3 |
| Rated Power | 360KW/450KVA |
| Frequency | 50Hz |
| Power Factor | 0.8 |
| Poles | 4 |
| Temperature Rise | 125K |
| Terminals | 12 |
| Insulation Class | H Class |
| Ambient Temperature | 40℃ |
| IP Rating | IP23 |
| Excitation System | Self-Excited |
| Bearing | Single Bearing |
| Coating | Vacuum Impregnation |
| Voltage Regulator | A.V.R |
| Coupling | Flexible Disc |
Control Panel
| ○ Emergency stop button | ○ Main circuit breaker |
| ○ Float battery charger | ○ Manual/Auto start control panel |
| ○ Fuel level meter | ○ Controller power switch |
| ○ Alarm buzzer |
Sound Attenuated Enclosure
○ Weatherproof sound-attenuated enclosure with internal exhaust silencer
○ Corrosion-resistant construction for outdoor installation
○ Available for GPC450S5-II silent type generator set
Options
○ ATS for automatic start and stop when utility power fails or returns
○ 12-hour fuel tank
○ 24-hour fuel tank
○ Water-jacket heater
○ Other heaters
○ AREM & PMG
○ Synchronization System
○ Remote & Monitoring System
Applications
The GENLITEC POWER 360kW/450kVA Cummins diesel generator set is suitable for prime and standby power applications where stable and dependable power is required, including:
○ Commercial buildings and office complexes
○ Industrial facilities and manufacturing plants
○ Construction sites and infrastructure projects
○ Mining and heavy-duty applications
○ Telecommunication and remote facilities
○ Data centers and critical power systems
○ Emergency and standby power applications
Why Choose GENLITEC POWER
GENLITEC POWER combines established engine technology, carefully selected generator components and professional assembly to provide reliable diesel generator sets for demanding power applications. The GPC450 series uses the Cummins KTA19-G3 engine and is configured to deliver 360kW/450kVA prime power with suitable engine reserve capacity.
○ Genuine Cummins KTA19-G3 diesel engine configuration
○ 360kW/450kVA prime power and 400kW/500kVA standby power
○ 19L six-cylinder turbocharged and aftercooled diesel engine
○ Cummins PT fuel system and direct injection
○ Approximately 403kW prime and 448kW standby engine output at 50Hz
○ 680L fuel tank for extended operating periods
○ High-quality alternator with H Class insulation and IP23 protection
○ Open and silent configurations for different installation requirements
○ ATS, synchronization and remote monitoring options available
○ Professional manufacturing, testing and international export experience
For more information, please visit the GENLITEC POWER® Why Choose GENLITEC POWER page.
Warranty