50Hz 400kW 500kVA Diesel Generator with Cummins KTA19-G3A Engine
Short Description
GENLITEC POWER GPC500D5-I/GPC500S5-I diesel gensets with Cummins KTA19-G3A, 400kW/500kVA prime and 440kW/550kVA standby power.
- ModelGPC500D5-II | GPC500S5-II
- Frequency50Hz
- Prime Power400KW/500KVA
- Standby Power440KW/550KVA
- EngineCummins KTA19-G3A
- AlternatorStamford/Leroy Somer/Genlitec Power
- Fuel Consumption (100% Load)91KG/H
- MOQ1 Set
Product Details
Product Tags
Introduction
The GENLITEC POWER® GPC500D5-II and GPC500S5-II are 500kVA Cummins diesel generator sets designed to provide reliable three-phase power for industrial, commercial, construction, mining, infrastructure and standby power applications. The generator sets are rated at 400kW/500kVA for prime power and 440kW/550kVA for standby power at 50Hz and 1500 RPM.
Powered by the Cummins KTA19-G3A six-cylinder, 19-liter diesel engine, the GPC500 series combines proven heavy-duty engine technology with a 400kW/500kVA generator output. The KTA19-G3A features a turbocharged and aftercooled air intake system, Cummins PT fuel system, four-cycle in-line six-cylinder configuration and water-cooled design. At 50Hz and 1500 RPM, the engine provides 448kW prime power and 504kW standby power.
The GPC500 generator set is available in both open and silent configurations. The GPC500D5-II open type is suitable for generator rooms and installations where easy maintenance and ventilation are required, while the GPC500S5-II silent type features a weatherproof sound-attenuated enclosure for outdoor and noise-sensitive applications. A 750L fuel tank is provided for extended operating periods, while ATS, synchronization, remote monitoring and other options are available for different project requirements.
Generator Set
| Open Type Model | GPC500D5-II |
| Silent Type Model | GPC500S5-II |
| Prime Power | 400KW/500KVA |
| Standby Power | 440KW/550KVA |
| Phase & Wire | 3 Phase, 4 Wires |
| Power Factor | 0.8 |
| Frequency | 50Hz |
| Voltage | 220/380V, 230/400V, 240/415V |
| Fuel Tank Capacity | 750L |
Diesel Engine
| Engine Model | CUMMINS KTA19-G3A |
| Engine Type | 4 Cycle, In-line, 6 Cylinder |
| Cylinder Number | 6 |
| Aspiration System | Turbocharged, Aftercooled |
| Cooling Method | Water Cooled |
| Fuel System | Cummins PT |
| Bore x Stroke | 159 x 159 mm |
| Compression Ratio | 13.9:1 |
| Displacement | 19L (1150 in³) |
| Rated Speed | 1500 RPM |
| Prime Power | 448KW (600 BHP) @ 1500 RPM |
| Standby Power | 504KW (675 BHP) @ 1500 RPM |
| Electric Starting System | DC 24V |
Fuel Consumption (KG/H)
| 100% Prime Load | 91 KG/H |
| 75% Prime Load | 70 KG/H |
| 50% Prime Load | 46 KG/H |
| 25% Prime Load | 24 KG/H |
Alternator
| Number of Phase | 3 |
| Rated Power | 400KW/500KVA |
| Frequency | 50Hz |
| Power Factor | 0.8 |
| Poles | 4 |
| Temperature Rise | 125K |
| Terminals | 6 (12 leads for option) |
| Insulation Class | H Class |
| Ambient Temperature | 40℃ |
| IP Rating | IP23 |
| Excitation System | Self-Excited |
| Bearing | Single Bearing |
| Coating | Vacuum Impregnation |
| Voltage Regulator | A.V.R |
| Coupling | Flexible Disc |
Control Panel
| ○ Emergency stop button | ○ Main circuit breaker |
| ○ Float battery charger | ○ Manual/Auto start control panel |
| ○ Fuel level meter | ○ Controller power switch |
| ○ Alarm buzzer |
Sound Attenuated Enclosure
○ Weatherproof sound-attenuated enclosure with internal exhaust silencer
○ Corrosion-resistant construction for outdoor installation
○ Available for GPC500S5-II silent type generator set
Options
○ ATS for automatic start and stop when utility power fails or returns
○ 12-hour fuel tank
○ 24-hour fuel tank
○ Water-jacket heater
○ Other heaters
○ AREM & PMG
○ Synchronization System
○ Remote & Monitoring System
Applications
The GENLITEC POWER 400kW/500kVA Cummins diesel generator set is suitable for prime and standby power applications where stable and dependable power is required, including:
○ Commercial buildings and office complexes
○ Industrial facilities and manufacturing plants
○ Construction sites and infrastructure projects
○ Mining and heavy-duty applications
○ Telecommunication and remote facilities
○ Data centers and critical power systems
○ Emergency and standby power applications
Why Choose GENLITEC POWER
GENLITEC POWER combines established engine technology, carefully selected generator components and professional assembly to provide reliable diesel generator sets for demanding power applications. The GPC500 series uses the Cummins KTA19-G3A engine and is configured to deliver 400kW/500kVA prime power with adequate engine reserve capacity.
○ Genuine Cummins KTA19-G3A diesel engine configuration
○ 400kW/500kVA prime power and 440kW/550kVA standby power
○ 19L six-cylinder turbocharged and aftercooled diesel engine
○ Cummins PT fuel system and proven heavy-duty engine design
○ 448kW prime and 504kW standby engine output at 50Hz and 1500 RPM
○ 750L fuel tank for extended operating periods
○ High-quality alternator with H Class insulation and IP23 protection
○ Open and silent configurations for different installation requirements
○ ATS, synchronization and remote monitoring options available
○ Professional manufacturing, testing and international export experience
For more information, please visit the GENLITEC POWER® Why Choose GENLITEC POWER page.
Warranty
GENLITEC POWER provides a standard warranty of 12 months or 1000 working hours, whichever comes first. For details, please refer to the GENLITEC POWER® Warranty Policy.