50Hz 400kW 500kVA Diesel Generator with Cummins KTA19-G3A Engine

50Hz 400kW 500kVA Diesel Generator with Cummins KTA19-G3A Engine - Image 1
  • 50Hz 400kW 500kVA Diesel Generator with Cummins KTA19-G3A Engine - Image 1
  • 50Hz 400kW 500kVA Diesel Generator with Cummins KTA19-G3A Engine - Image 2
  • 50Hz 400kW 500kVA Diesel Generator with Cummins KTA19-G3A Engine - Image 3
  • 50Hz 400kW 500kVA Diesel Generator with Cummins KTA19-G3A Engine - Image 4

Short Description

GENLITEC POWER GPC500D5-I/GPC500S5-I diesel gensets with Cummins KTA19-G3A, 400kW/500kVA prime and 440kW/550kVA standby power.

  • ModelGPC500D5-II | GPC500S5-II
  • Frequency50Hz
  • Prime Power400KW/500KVA
  • Standby Power440KW/550KVA
  • EngineCummins KTA19-G3A
  • AlternatorStamford/Leroy Somer/Genlitec Power
  • Fuel Consumption (100% Load)91KG/H
  • MOQ1 Set

Product Details

Product Tags

500kVA Cummins KTA19-G3A diesel generator set GPC500D5-II open type and GPC500S5-II silent type

Introduction

The GENLITEC POWER® GPC500D5-II and GPC500S5-II are 500kVA Cummins diesel generator sets designed to provide reliable three-phase power for industrial, commercial, construction, mining, infrastructure and standby power applications. The generator sets are rated at 400kW/500kVA for prime power and 440kW/550kVA for standby power at 50Hz and 1500 RPM.

Powered by the Cummins KTA19-G3A six-cylinder, 19-liter diesel engine, the GPC500 series combines proven heavy-duty engine technology with a 400kW/500kVA generator output. The KTA19-G3A features a turbocharged and aftercooled air intake system, Cummins PT fuel system, four-cycle in-line six-cylinder configuration and water-cooled design. At 50Hz and 1500 RPM, the engine provides 448kW prime power and 504kW standby power.

The GPC500 generator set is available in both open and silent configurations. The GPC500D5-II open type is suitable for generator rooms and installations where easy maintenance and ventilation are required, while the GPC500S5-II silent type features a weatherproof sound-attenuated enclosure for outdoor and noise-sensitive applications. A 750L fuel tank is provided for extended operating periods, while ATS, synchronization, remote monitoring and other options are available for different project requirements.

Generator Set

Open Type Model GPC500D5-II
Silent Type Model GPC500S5-II
Prime Power 400KW/500KVA
Standby Power 440KW/550KVA
Phase & Wire 3 Phase, 4 Wires
Power Factor 0.8
Frequency 50Hz
Voltage 220/380V, 230/400V, 240/415V
Fuel Tank Capacity 750L

Diesel Engine

Engine Model CUMMINS KTA19-G3A
Engine Type 4 Cycle, In-line, 6 Cylinder
Cylinder Number 6
Aspiration System Turbocharged, Aftercooled
Cooling Method Water Cooled
Fuel System Cummins PT
Bore x Stroke 159 x 159 mm
Compression Ratio 13.9:1
Displacement 19L (1150 in³)
Rated Speed 1500 RPM
Prime Power 448KW (600 BHP) @ 1500 RPM
Standby Power 504KW (675 BHP) @ 1500 RPM
Electric Starting System DC 24V

Fuel Consumption (KG/H)

100% Prime Load 91 KG/H
75% Prime Load 70 KG/H
50% Prime Load 46 KG/H
25% Prime Load 24 KG/H

Alternator

Number of Phase 3
Rated Power 400KW/500KVA
Frequency 50Hz
Power Factor 0.8
Poles 4
Temperature Rise 125K
Terminals 6 (12 leads for option)
Insulation Class H Class
Ambient Temperature 40℃
IP Rating IP23
Excitation System Self-Excited
Bearing Single Bearing
Coating Vacuum Impregnation
Voltage Regulator A.V.R
Coupling Flexible Disc

Control Panel

○ Emergency stop button ○ Main circuit breaker
○ Float battery charger ○ Manual/Auto start control panel
○ Fuel level meter ○ Controller power switch
○ Alarm buzzer

Sound Attenuated Enclosure

○ Weatherproof sound-attenuated enclosure with internal exhaust silencer

○ Corrosion-resistant construction for outdoor installation

○ Available for GPC500S5-II silent type generator set

Options

○ ATS for automatic start and stop when utility power fails or returns

○ 12-hour fuel tank

○ 24-hour fuel tank

○ Water-jacket heater

○ Other heaters

○ AREM & PMG

○ Synchronization System

○ Remote & Monitoring System

Applications

The GENLITEC POWER 400kW/500kVA Cummins diesel generator set is suitable for prime and standby power applications where stable and dependable power is required, including:

○ Commercial buildings and office complexes

○ Industrial facilities and manufacturing plants

○ Construction sites and infrastructure projects

○ Mining and heavy-duty applications

○ Telecommunication and remote facilities

○ Data centers and critical power systems

○ Emergency and standby power applications

Why Choose GENLITEC POWER

GENLITEC POWER combines established engine technology, carefully selected generator components and professional assembly to provide reliable diesel generator sets for demanding power applications. The GPC500 series uses the Cummins KTA19-G3A engine and is configured to deliver 400kW/500kVA prime power with adequate engine reserve capacity.

○ Genuine Cummins KTA19-G3A diesel engine configuration

○ 400kW/500kVA prime power and 440kW/550kVA standby power

○ 19L six-cylinder turbocharged and aftercooled diesel engine

○ Cummins PT fuel system and proven heavy-duty engine design

○ 448kW prime and 504kW standby engine output at 50Hz and 1500 RPM

○ 750L fuel tank for extended operating periods

○ High-quality alternator with H Class insulation and IP23 protection

○ Open and silent configurations for different installation requirements

○ ATS, synchronization and remote monitoring options available

○ Professional manufacturing, testing and international export experience

For more information, please visit the GENLITEC POWER® Why Choose GENLITEC POWER page.

Warranty

GENLITEC POWER provides a standard warranty of 12 months or 1000 working hours, whichever comes first. For details, please refer to the GENLITEC POWER® Warranty Policy.

Frequently Asked Questions

Q: What is the rated power of the GPC500 Cummins diesel generator set?
A: The GPC500D5-II open type and GPC500S5-II silent type are rated at 400kW/500kVA for prime power and 440kW/550kVA for standby power at 50Hz.
Q: Which Cummins engine is used in the 500kVA generator?
A: The GPC500 series is powered by the Cummins KTA19-G3A, a six-cylinder 19L diesel engine with turbocharged and aftercooled technology, Cummins PT fuel system and 1500 RPM rated speed.
Q: What is the Cummins KTA19-G3A engine output at 50Hz?
A: At 50Hz and 1500 RPM, the Cummins KTA19-G3A provides 448kW (600 BHP) prime power and 504kW (675 BHP) standby power. The GENLITEC POWER GPC500 generator set is rated at 400kW/500kVA prime and 440kW/550kVA standby.
Q: What is the fuel tank capacity and fuel consumption?
A: The standard GPC500 configuration is equipped with a 750L fuel tank. Fuel consumption is approximately 91KG/H at 100% prime load, 70KG/H at 75% load, 46KG/H at 50% load and 24KG/H at 25% load.
Q: What voltage and frequency can the GPC500 generator provide?
A: The standard configuration is 50Hz, three-phase, four-wire output. Available voltage configurations include 220/380V, 230/400V and 240/415V, depending on the selected alternator configuration and project requirements.
Q: What is the difference between the GPC500D5-II and GPC500S5-II?
A: Both models use the same Cummins KTA19-G3A engine and generator rating. The GPC500D5-II is an open type generator set designed mainly for generator rooms and installations with suitable ventilation, while the GPC500S5-II uses a weatherproof sound-attenuated enclosure for outdoor and noise-sensitive applications.
Q: Is the GPC500 suitable for prime power applications?
A: Yes. The GPC500 series is rated at 400kW/500kVA prime power and is suitable for long-duration power applications when operated within the specified load profile, environmental conditions and maintenance requirements.
Q: Can the GPC500 be configured for automatic operation or parallel operation?
A: Yes. ATS, automatic start and stop, synchronization and paralleling systems, remote monitoring, water-jacket heaters and other options can be configured according to the project requirements.
Q: Where can the 500kVA Cummins generator be used?
A: The GPC500 series is suitable for factories, commercial buildings, construction sites, mining projects, infrastructure, telecommunications, data centers and other applications requiring reliable prime or standby power.
Q: What warranty is provided for the GPC500 series?
A: The standard warranty is 12 months or 1000 working hours, whichever comes first.

  • Previous: 900KVA Perkins Diesel Generator-60Hz
  • Next: 500KVA Deutz Diesel Generator-50Hz