50Hz 500kW 625kVA Diesel Generator with Cummins KTAA19-G6A Engine

50Hz 500kW 625kVA Diesel Generator with Cummins KTAA19-G6A Engine - Image 1
  • 50Hz 500kW 625kVA Diesel Generator with Cummins KTAA19-G6A Engine - Image 1
  • 50Hz 500kW 625kVA Diesel Generator with Cummins KTAA19-G6A Engine - Image 2
  • 50Hz 500kW 625kVA Diesel Generator with Cummins KTAA19-G6A Engine - Image 3
  • 50Hz 500kW 625kVA Diesel Generator with Cummins KTAA19-G6A Engine - Image 4

Short Description

GENLITEC POWER GPC625D5/GPC625S5 625kVA diesel generator powered by CUMMINS KTAA19-G6A, delivering 500kW prime and 550kW standby power.

  • ModelGPC625D5 | GPC625S5
  • Frequency50Hz
  • Prime Power500KW/625KVA
  • Standby Power550KW/688KVA
  • EngineCummins KTAA19-G6A
  • AlternatorStamford/Leroy Somer/Genlitec Power
  • Fuel Consumption (100% Load)127.8L/H
  • MOQ1 Set

Product Details

Product Tags

625kVA Cummins KTAA19-G6A diesel generator set GPC625D5 open type and GPC625S5 silent type

Introduction

The GENLITEC POWER® GPC625D5 and GPC625S5 are 625kVA Cummins diesel generator sets designed to provide reliable three-phase power for industrial, commercial, construction, mining, infrastructure and standby power applications. The generator sets are rated at 500kW/625kVA for prime power and 550kW/688kVA for standby power at 50Hz and 1500 RPM.

Powered by the Cummins KTAA19-G6A six-cylinder, 19-liter diesel engine, the GPC625 series combines proven heavy-duty engine technology with a 500kW/625kVA generator output. The KTAA19-G6A features a turbocharged and air-to-air cooled air intake system, Cummins PT fuel pump system, electronic governor and water-cooled design. With a rated engine power of 520kW at 1500 RPM, the engine provides sufficient power reserve for demanding generator applications.

The GPC625 generator set is available in both open and silent configurations. The GPC625D5 open type is suitable for generator rooms and installations where easy maintenance and ventilation are required, while the GPC625S5 silent type features a weatherproof sound-attenuated enclosure for outdoor and noise-sensitive applications. A 950L fuel tank is provided for extended operating periods, while ATS, synchronization, remote monitoring and other options are available for different project requirements.

Generator Set

Open Type Model GPC625D5
Silent Type Model GPC625S5
Prime Power 500KW/625KVA
Standby Power 550KW/688KVA
Phase & Wires 3 Phase, 4 Wires
Power Factor 0.8
Frequency 50Hz
Rated Voltage 220/380V, 230/400V, 240/415V
Fuel Tank Capacity 950L

Diesel Engine

Model CUMMINS KTAA19-G6A
Cylinder Number 6
Aspiration System Turbocharged, Air to Air Cooled
Cooling Method Water Cooled
Governor Type Electronic
Bore x Stroke 159 x 159 mm
Compression Ratio 13.9:1
Rated Speed 1500RPM
Displacement 19L
Rated Power /
Standby Power 610KW
Coolant Capacity /
Oil Capacity 50L
Fuel System CUMMINS PT Pump
Electric Starting System DC 24V

Fuel Consumption (L/H)

100% Prime Load 127.8 L/H
75% Prime Load 95.2 L/H
50% Prime Load 63.9 L/H

Alternator

Number of Phase 3
Rated Power 500KW/625KVA
Frequency 50Hz
Power Factor 0.8
Poles 4
Temp. Rise 125K
Terminals 12
Insulation Class H Class
Ambient Temp. 40℃
IP Rating IP23
Excitation System Self-Excited
Bearing Single Bearing
Coating Vacuum Impregnation
Voltage Regulator A.V.R
Coupling Flexible Disc

Control Panel

○ Emergency stop button ○ Main circuit breaker
○ Float battery charger ○ Manual/Auto start control panel
○ Fuel level meter ○ Controller power switch
○ Alarm buzzer

Sound Attenuated Enclosure

○ Weatherproof sound-attenuated enclosure with internal exhaust silencer

○ Corrosion-resistant construction for outdoor installation

○ Available for GPC625S5 silent type generator set

Options

○ ATS for automatic start and stop when utility power fails or returns

○ 12-hour fuel tank

○ 24-hour fuel tank

○ Water-jacket heater

○ Other heaters

○ AREM & PMG

○ Synchronization System

○ Remote & Monitoring System

Applications

The GENLITEC POWER 500kW/625kVA Cummins KTAA19-G6A diesel generator set is suitable for prime and standby power applications where stable and dependable power is required, including:

○ Commercial buildings and office complexes

○ Industrial facilities and manufacturing plants

○ Construction sites and infrastructure projects

○ Mining and heavy-duty applications

○ Telecommunication and remote facilities

○ Data centers and critical power systems

○ Emergency and standby power applications

Why Choose GENLITEC POWER

GENLITEC POWER combines established engine technology, carefully selected generator components and professional assembly to provide reliable diesel generator sets for demanding power applications. The GPC625 series uses the Cummins KTAA19-G6A engine and is configured to deliver 500kW/625kVA prime power with sufficient engine reserve capacity.

○ Genuine Cummins KTAA19-G6A diesel engine configuration

○ 500kW/625kVA prime power and 550kW/688kVA standby power

○ 19L six-cylinder turbocharged and air-to-air cooled diesel engine

○ Cummins PT fuel pump system and electronic governor

○ 520kW rated engine power and 570kW standby engine power

○ 950L fuel tank for extended operating periods

○ High-quality alternator with H Class insulation and IP23 protection

○ Open and silent configurations for different installation requirements

○ ATS, synchronization and remote monitoring options available

○ Professional manufacturing, testing and international export experience

For more information, please visit the GENLITEC POWER® Why Choose GENLITEC POWER page.

Warranty

GENLITEC POWER provides a standard warranty of 12 months or 1000 working hours, whichever comes first. For details, please refer to the GENLITEC POWER® Warranty Policy.

Frequently Asked Questions

Q: What is the rated power of the GPC625 Cummins diesel generator set?
A: The GPC625D5 open type and GPC625S5 silent type are rated at 500kW/625kVA for prime power and 550kW/688kVA for standby power at 50Hz.
Q: Which Cummins engine is used in the 625kVA generator?
A: The GPC625 series is powered by the Cummins KTAA19-G6A, a six-cylinder 19L diesel engine with turbocharged and air-to-air cooled technology, Cummins PT fuel pump system, electronic governor and 1500 RPM rated speed.
Q: What is the rated power of the Cummins KTAA19-G6A engine?
A: The Cummins KTAA19-G6A engine is rated at 520kW, with a standby power rating of 570kW at 1500 RPM. The GENLITEC POWER GPC625 generator set is rated at 500kW/625kVA prime and 550kW/688kVA standby.
Q: What is the fuel tank capacity and fuel consumption?
A: The standard GPC625 configuration is equipped with a 950L fuel tank. Fuel consumption is 127.8 L/H at 100% prime load, 95.2 L/H at 75% load and 63.9 L/H at 50% load.
Q: What voltage and frequency can the GPC625 generator provide?
A: The standard configuration is 50Hz, three-phase, four-wire output. Available voltage configurations include 220/380V, 230/400V and 240/415V, depending on the selected alternator configuration and project requirements.
Q: What is the difference between the GPC625D5 and GPC625S5?
A: Both models use the same Cummins KTAA19-G6A engine and generator rating. The GPC625D5 is an open type generator set designed mainly for generator rooms and installations with suitable ventilation, while the GPC625S5 uses a weatherproof sound-attenuated enclosure for outdoor and noise-sensitive applications.
Q: Is the GPC625 suitable for prime power applications?
A: Yes. The GPC625 series is rated at 500kW/625kVA prime power and is suitable for long-duration power applications when operated within the specified load profile, environmental conditions and maintenance requirements.
Q: Can the GPC625 be configured for automatic operation or parallel operation?
A: Yes. ATS, automatic start and stop, synchronization and paralleling systems, remote monitoring, water-jacket heaters and other options can be configured according to the project requirements.
Q: Where can the 625kVA Cummins generator be used?
A: The GPC625 series is suitable for factories, commercial buildings, construction sites, mining projects, infrastructure, telecommunications, data centers and other applications requiring reliable prime or standby power.
Q: What warranty is provided for the GPC625 series?
A: The standard warranty is 12 months or 1000 working hours, whichever comes first.

  • Previous: 1250KVA Perkins Diesel Generator-60Hz
  • Next: 563KVA Deutz Diesel Generator-50Hz