50Hz 520kW 650kVA Diesel Generator with Cummins QSK19-G4 Engine

50Hz 520kW 650kVA Diesel Generator with Cummins QSK19-G4 Engine - Image 1
  • 50Hz 520kW 650kVA Diesel Generator with Cummins QSK19-G4 Engine - Image 1
  • 50Hz 520kW 650kVA Diesel Generator with Cummins QSK19-G4 Engine - Image 2
  • 50Hz 520kW 650kVA Diesel Generator with Cummins QSK19-G4 Engine - Image 3
  • 50Hz 520kW 650kVA Diesel Generator with Cummins QSK19-G4 Engine - Image 4

Short Description

GENLITEC GPC650D5/GPC650S5, prime power 520kW/650kVA diesel generator sets, 50Hz, for reliable industrial, commercial and backup power applications.

  • ModelGPC650D5 | GPC650S5
  • Frequency50Hz
  • Prime Power520KW/650KVA
  • Standby Power570KW/712KVA
  • EngineCummins QSK19-G4
  • AlternatorStamford/Leroy Somer/Genlitec Power
  • Fuel Consumption (100% Load)145L/H
  • MOQ1 Set

Product Details

Product Tags

650kVA Cummins QSK19-G4 diesel generator set GPC650D5 open type and GPC650S5 silent type

Introduction

The GENLITEC POWER® GPC650D5 and GPC650S5 are 650kVA Cummins diesel generator sets designed to provide reliable three-phase power for industrial, commercial, construction, mining, infrastructure and standby power applications. The generator sets are rated at 520kW/650kVA for prime power and 570kW/712kVA for standby power at 50Hz and 1500 RPM.

Powered by the Cummins QSK19-G4 six-cylinder, 19-liter diesel engine, the GPC650 series combines heavy-duty engine technology with a 520kW/650kVA generator output. The QSK19-G4 features a turbocharged and charge air cooled air intake system, electronic governor, water-cooled design and Cummins direct injection MCRS fuel system. With a rated engine power of 574kW at 1500 RPM, the engine provides sufficient power reserve for demanding generator applications.

The GPC650 generator set is available in both open and silent configurations. The GPC650D5 open type is suitable for generator rooms and installations where easy maintenance and ventilation are required, while the GPC650S5 silent type features a weatherproof sound-attenuated enclosure for outdoor and noise-sensitive applications. A 1000L fuel tank is provided for extended operating periods, while ATS, synchronization, remote monitoring and other options are available for different project requirements.

Generator Set

Open Type Model GPC650D5
Silent Type Model GPC650S5
Prime Power 520KW/650KVA
Standby Power 570KW/712KVA
Phase & Wires 3 Phase, 4 Wires
Power Factor 0.8
Frequency 50Hz
Rated Voltage 220/380V, 230/400V, 240/415V
Fuel Tank Capacity 1000L

Diesel Engine

Engine Model QSK19-G4
Cylinder Number 6
Aspiration System Turbo Charged, Charge Air Cooled
Cooling Method Water Cooled
Governor Type Electronic
Bore x Stroke 159 x 159 mm
Compression Ratio 15:1
Rated Speed 1500 RPM
Displacement 19L
Rated Power 574KW
Standby Power 634KW
Coolant Capacity 41.6L (Engine Only)
Oil Capacity 84L
Fuel System CUMMINS Direct Injection MCRS
Electric Starting System DC 24V

Fuel Consumption (L/H)

100% Prime Load 145L/H
75% Prime Load 111L/H
50% Prime Load 79L/H
25% Prime Load 41L/H

Alternator

Number of Phase 3
Rated Power 520KW/650KVA
Frequency 50Hz
Power Factor 0.8
Poles 4
Temp. Rise 125K
Terminals 12
Insulation Class H
Ambient Temp. 40℃
IP Rating IP23
Excitation System Self-Excited
Bearing Single Bearing
Coating Vacuum Impregnation
Voltage Regulator A.V.R
Coupling Flexible Disc

Control Panel

○ Emergency stop button ○ Main circuit breaker
○ Float battery charger ○ Manual/Auto start control panel
○ Fuel level meter ○ Controller power switch
○ Alarm buzzer

Sound Attenuated Enclosure

○ Weatherproof sound-attenuated enclosure with internal exhaust silencer

○ Corrosion-resistant construction for outdoor installation

○ Available for GPC650S5 silent type generator set

Options

○ ATS for automatic start and stop when utility power fails or returns

○ 12-hour fuel tank

○ 24-hour fuel tank

○ Water-jacket heater

○ Other heaters

○ AREM & PMG

○ Synchronization System

○ Remote & Monitoring System

Applications

The GENLITEC POWER 520kW/650kVA Cummins QSK19-G4 diesel generator set is suitable for prime and standby power applications where stable and dependable power is required, including:

○ Commercial buildings and office complexes

○ Industrial facilities and manufacturing plants

○ Construction sites and infrastructure projects

○ Mining and heavy-duty applications

○ Telecommunication and remote facilities

○ Data centers and critical power systems

○ Emergency and standby power applications

Why Choose GENLITEC POWER

GENLITEC POWER combines established engine technology, carefully selected generator components and professional assembly to provide reliable diesel generator sets for demanding power applications. The GPC650 series uses the Cummins QSK19-G4 engine and is configured to deliver 520kW/650kVA prime power with sufficient engine reserve capacity.

○ Genuine Cummins QSK19-G4 diesel engine configuration

○ 520kW/650kVA prime power and 570kW/712kVA standby power

○ 19L six-cylinder turbocharged and charge air cooled diesel engine

○ Cummins direct injection MCRS fuel system and electronic governor

○ 574kW rated engine power and 634kW standby engine power

○ 1000L fuel tank for extended operating periods

○ High-quality alternator with H Class insulation and IP23 protection

○ Open and silent configurations for different installation requirements

○ ATS, synchronization and remote monitoring options available

○ Professional manufacturing, testing and international export experience

For more information, please visit the GENLITEC POWER® Why Choose GENLITEC POWER page.

Warranty

GENLITEC POWER provides a standard warranty of 12 months or 1000 working hours, whichever comes first. For details, please refer to the GENLITEC POWER® Warranty Policy.

Frequently Asked Questions

Q: What is the rated power of the GPC650 Cummins diesel generator set?
A: The GPC650D5 open type and GPC650S5 silent type are rated at 520kW/650kVA for prime power and 570kW/712kVA for standby power at 50Hz.
Q: Which Cummins engine is used in the 650kVA generator?
A: The GPC650 series is powered by the Cummins QSK19-G4, a six-cylinder 19L diesel engine with turbocharged and charge air cooled technology, electronic governor, direct injection MCRS fuel system and 1500 RPM rated speed.
Q: What is the rated power of the Cummins QSK19-G4 engine?
A: The Cummins QSK19-G4 engine is rated at 574kW, with a standby power rating of 634kW at 1500 RPM. The GENLITEC POWER GPC650 generator set is rated at 520kW/650kVA prime and 570kW/712kVA standby.
Q: What is the fuel tank capacity and fuel consumption?
A: The standard GPC650 configuration is equipped with a 1000L fuel tank. Fuel consumption is approximately 145L/H at 100% prime load, 111L/H at 75% load, 79L/H at 50% load and 41L/H at 25% load.
Q: What voltage and frequency can the GPC650 generator provide?
A: The standard configuration is 50Hz, three-phase, four-wire output. Available voltage configurations include 220/380V, 230/400V and 240/415V, depending on the selected alternator configuration and project requirements.
Q: What is the difference between the GPC650D5 and GPC650S5?
A: Both models use the same Cummins QSK19-G4 engine and generator rating. The GPC650D5 is an open type generator set designed mainly for generator rooms and installations with suitable ventilation, while the GPC650S5 uses a weatherproof sound-attenuated enclosure for outdoor and noise-sensitive applications.
Q: Is the GPC650 suitable for prime power applications?
A: Yes. The GPC650 series is rated at 520kW/650kVA prime power and is suitable for long-duration power applications when operated within the specified load profile, environmental conditions and maintenance requirements.
Q: Can the GPC650 be configured for automatic operation or parallel operation?
A: Yes. ATS, automatic start and stop, synchronization and paralleling systems, remote monitoring, water-jacket heaters and other options can be configured according to the project requirements.
Q: Where can the 650kVA Cummins generator be used?
A: The GPC650 series is suitable for factories, commercial buildings, construction sites, mining projects, infrastructure, telecommunications, data centers and other applications requiring reliable prime or standby power.
Q: What warranty is provided for the GPC650 series?
A: The standard warranty is 12 months or 1000 working hours, whichever comes first.

  • Previous: 1350KVA Perkins Diesel Generator-60Hz
  • Next: 688KVA Deutz Diesel Generator-50Hz

  • Related Products