50Hz 600kW 750kVA Diesel Generator with Cummins KTA38-G2 Engine
Short Description
GENLITEC GPC750D5/GPC750S5, prime power 600kW/750kVA diesel generator sets, 50Hz, for reliable industrial, commercial and backup power applications.
- ModelGPC750D5 | GPC750S5
- Frequency50Hz
- Prime Power600KW/750KVA
- Standby Power660KW/825KVA
- EngineCummins KT38-G2
- AlternatorStamford/Leroy Somer/Genlitec Power
- Fuel Consumption (100% Load)142kg/H
- MOQ1 Set
Product Details
Product Tags
Introduction
The GENLITEC POWER® GPC750D5 and GPC750S5 are 750kVA Cummins diesel generator sets designed to provide reliable three-phase power for industrial, commercial, construction, mining, infrastructure and standby power applications. The generator sets are rated at 600kW/750kVA for prime power and 660kW/825kVA for standby power at 50Hz, with 1500 RPM operation.
Powered by the Cummins KTA38-G2 V12, 38-liter diesel engine, the GPC750 series combines high engine capacity with a 600kW/750kVA alternator output. The Cummins KTA38-G2 uses a turbocharged and aftercooled configuration, Cummins PT fuel system, direct injection and a 14.5:1 compression ratio. At 50Hz and 1500 RPM, the engine provides approximately 664kW prime output and 731kW standby output, providing suitable engine capacity for the rated generator set output.
The GPC750 generator set is available in both open and silent configurations. The GPC750D5 open type is suitable for generator rooms and installations where easy maintenance and ventilation are required, while the GPC750S5 silent type features a weatherproof sound-attenuated enclosure for outdoor and noise-sensitive applications. A 1000L fuel tank is provided for extended operating periods, while ATS, synchronization, remote monitoring and other options are available for different project requirements.
Generator Set
| Open Type Model | GPC750D5 |
| Silent Type Model | GPC750S5 |
| Prime Power | 600KW/750KVA |
| Standby Power | 660KW/825KVA |
| Phase & Wire | 3 Phase, 4 Wires |
| Power Factor | 0.8 |
| Frequency | 50Hz |
| Voltage | 220/380V, 230/400V, 240/415V |
| Fuel Tank Capacity | 1000L |
Diesel Engine
| Engine Model | CUMMINS KTA38-G2 |
| Cylinder Number | V-12 |
| Aspiration System | Turbocharged, Aftercooled |
| Cooling Method | Water Cooled |
| Governor Type | Electronic |
| Bore x Stroke | 159 x 159 mm |
| Compression Ratio | 14.5:1 |
| Rated Speed | 1500 RPM |
| Displacement | 38L |
| Prime Power | 664KW |
| Standby Power | 731KW |
| Fuel System | Cummins PT, Direct Injection |
| Electric Starting System | DC 24V |
Fuel Consumption
| 100% Prime Load | 142kg/H |
| 75% Prime Load | 109kg/H |
| 50% Prime Load | 72kg/H |
| 25% Prime Load | 41kg/H |
Alternator
| Number of Phase | 3 |
| Rated Power | 600KW/750KVA |
| Frequency | 50Hz |
| Power Factor | 0.8 |
| Poles | 4 |
| Temperature Rise | 125K |
| Terminals | 12 |
| Insulation Class | H Class |
| Ambient Temperature | 40℃ |
| IP Rating | IP23 |
| Excitation System | Self-Excited |
| Bearing | Single Bearing |
| Coating | Vacuum Impregnation |
| Voltage Regulator | A.V.R |
| Coupling | Flexible Disc |
Control Panel
| ○ Emergency stop button | ○ Main circuit breaker |
| ○ Float battery charger | ○ Manual/Auto start control panel |
| ○ Fuel level meter | ○ Controller power switch |
| ○ Alarm buzzer |
Sound Attenuated Enclosure
○ Weatherproof sound-attenuated enclosure with internal exhaust silencer
○ Corrosion-resistant construction for outdoor installation
○ Available for GPC750S5 silent type generator set
Options
○ ATS for automatic start and stop when utility power fails or returns
○ 12-hour fuel tank
○ 24-hour fuel tank
○ Water-jacket heater
○ Other heaters
○ AREM & PMG
○ Synchronization System
○ Remote & Monitoring System
Applications
The GENLITEC POWER 600kW/750kVA Cummins diesel generator set is suitable for prime and standby power applications where stable and dependable power is required, including:
○ Commercial buildings and office complexes
○ Industrial facilities and manufacturing plants
○ Construction sites and infrastructure projects
○ Mining and heavy-duty applications
○ Telecommunication and remote facilities
○ Data centers and critical power systems
○ Emergency and standby power applications
Why Choose GENLITEC POWER
GENLITEC POWER combines established engine technology, carefully selected generator components and professional assembly to provide reliable diesel generator sets for demanding power applications. The GPC750 series uses the Cummins KTA38-G2 engine and is configured to deliver 600kW/750kVA prime power with suitable engine reserve capacity.
○ Genuine Cummins KTA38-G2 diesel engine configuration
○ 600kW/750kVA prime power and 660kW/825kVA standby power
○ 38L V-12 turbocharged and aftercooled diesel engine
○ Cummins PT fuel system and direct injection
○ Approximately 664kW prime and 731kW standby engine output at 50Hz
○ 1000L fuel tank for extended operating periods
○ High-quality alternator with H Class insulation and IP23 protection
○ Open and silent configurations for different installation requirements
○ ATS, synchronization and remote monitoring options available
○ Professional manufacturing, testing and international export experience
For more information, please visit the GENLITEC POWER® Why Choose GENLITEC POWER page.
Warranty
GENLITEC POWER provides a standard warranty of 12 months or 1000 working hours, whichever comes first. For details, please refer to the GENLITEC POWER® Warranty Policy.









