50Hz 640kW 800kVA Diesel Generator with Cummins KTA38-G2B Engine

50Hz 640kW 800kVA Diesel Generator with Cummins KTA38-G2B Engine - Image 1
  • 50Hz 640kW 800kVA Diesel Generator with Cummins KTA38-G2B Engine - Image 1
  • 50Hz 640kW 800kVA Diesel Generator with Cummins KTA38-G2B Engine - Image 2
  • 50Hz 640kW 800kVA Diesel Generator with Cummins KTA38-G2B Engine - Image 3
  • 50Hz 640kW 800kVA Diesel Generator with Cummins KTA38-G2B Engine - Image 4

Short Description

800kVA Cummins KTA38-G2B diesel generator, 640kW prime and 704kW standby power. GENLITEC POWER GPC800D5/GPC800S5 open and silent types.

  • ModelGPC800D5 | GPC800S5
  • Frequency50Hz
  • Prime Power640KW/800KVA
  • Standby Power704KW/880KVA
  • EngineCummins KTA38-G2B
  • AlternatorStamford/Leroy Somer/Genlitec Power
  • Fuel Consumption (100% Load)142kg/H
  • MOQ1 Set

Product Details

Product Tags

800kVA Cummins KTA38-G2B diesel generator set GPC800D5 open type and GPC800S5 silent type

Introduction

The GENLITEC POWER® GPC800D5 and GPC800S5 are 800kVA Cummins diesel generator sets designed to provide reliable three-phase power for industrial, commercial, construction, mining, infrastructure and standby power applications. The generator sets are rated at 640kW/800kVA for prime power and 700kW/880kVA for standby power at 50Hz, with 1500 RPM operation.

Powered by the Cummins KTA38-G2B 12-cylinder, 38-liter diesel engine, the GPC800 series combines high engine capacity with a 640kW/800kVA alternator output. The Cummins KTA38-G2B uses a turbocharged, water/air-cooled aspiration system, Cummins PT fuel pump, electronic governor and a 14.5:1 compression ratio. At 50Hz and 1500 RPM, the engine provides 711kW rated power and 790kW standby power, providing suitable engine capacity for the rated generator set output.

The GPC800 generator set is available in both open and silent configurations. The GPC800D5 open type is suitable for generator rooms and installations where easy maintenance and ventilation are required, while the GPC800S5 silent type features a weatherproof sound-attenuated enclosure for outdoor and noise-sensitive applications. A 1200L fuel tank is provided for extended operating periods, while ATS, synchronization, remote monitoring and other options are available for different project requirements.

Generator Set

Open Type Model GPC800D5
Silent Type Model GPC800S5
Prime Power 640KW/800KVA
Standby Power 700KW/880KVA
Phase & Wire 3 Phase, 4 Wires
Power Factor 0.8
Frequency 50Hz
Voltage 220/380V, 230/400V, 240/415V
Fuel Tank Capacity 1000L

Diesel Engine

Engine Model CUMMINS KTA38-G2B
Cylinder Number 12-V
Aspiration System Turbo, Water/Air Cooled
Cooling Method Water Cooled
Governor Type EFC Electronic
Bore x Stroke 159 x 159 mm
Compression Ratio 14.5:1
Rated Speed 1500 RPM
Displacement 38L
Prime Power 711KW
Standby Power 790KW
Fuel System CUMMINS PT Pump
Electric Starting System DC 24V

Fuel Consumption

100% Prime Load 142KG/H
75% Prime Load 109KG/H
50% Prime Load 77KG/H
25% Prime Load 45KG/H

Alternator

Number of Phase 3
Rated Power 640KW/800KVA
Frequency 50Hz
Power Factor 0.8
Poles 4
Temperature Rise 125K
Terminals 12
Insulation Class H
Ambient Temperature 40℃
IP Rating IP23
Excitation System Self-Excited
Bearing Single Bearing
Coating Vacuum Impregnation
Voltage Regulator A.V.R
Coupling Flexible Disc

Control Panel

○ Emergency stop button ○ Main circuit breaker
○ Float battery charger ○ Manual/Auto start control panel
○ Fuel level meter ○ Controller power switch
○ Alarm buzzer

Sound Attenuated Enclosure

○ Weatherproof sound-attenuated enclosure with internal exhaust silencer

○ Corrosion-resistant construction for outdoor installation

○ Available for GPC800S5 silent type generator set

Options

○ ATS for automatic start and stop when utility power fails or returns

○ 12-hour fuel tank

○ 24-hour fuel tank

○ Water-jacket heater

○ Other heaters

○ AREM & PMG

○ Synchronization System

○ Remote & Monitoring System

Applications

The GENLITEC POWER 640kW/800kVA Cummins diesel generator set is suitable for prime and standby power applications where stable and dependable power is required, including:

○ Commercial buildings and office complexes

○ Industrial facilities and manufacturing plants

○ Construction sites and infrastructure projects

○ Mining and heavy-duty applications

○ Telecommunication and remote facilities

○ Data centers and critical power systems

○ Emergency and standby power applications

Why Choose GENLITEC POWER

GENLITEC POWER combines established engine technology, carefully selected generator components and professional assembly to provide reliable diesel generator sets for demanding power applications. The GPC800 series uses the Cummins KTA38-G2B engine and is configured to deliver 640kW/800kVA prime power with suitable engine reserve capacity.

○ Genuine Cummins KTA38-G2B diesel engine configuration

○ 640kW/800kVA prime power and 700kW/880kVA standby power

○ 38L 12-cylinder turbocharged diesel engine

○ Cummins PT fuel pump and EFC electronic governor

○ 711kW rated and 790kW standby engine output at 50Hz

○ 1200L fuel tank for extended operating periods

○ High-quality alternator with H Class insulation and IP23 protection

○ Open and silent configurations for different installation requirements

○ ATS, synchronization and remote monitoring options available

○ Professional manufacturing, testing and international export experience

For more information, please visit the GENLITEC POWER® Why Choose GENLITEC POWER page.

Warranty

GENLITEC POWER provides a standard warranty of 12 months or 1000 working hours, whichever comes first. For details, please refer to the GENLITEC POWER® Warranty Policy.

Frequently Asked Questions

Q: What is the rated power of the GPC800 Cummins diesel generator set?
A: The GPC800D5 open type and GPC800S5 silent type are rated at 640kW/800kVA for prime power and 700kW/880kVA for standby power at 50Hz.
Q: Which Cummins engine is used in the 800kVA generator?
A: The GPC800 series is powered by the Cummins KTA38-G2B, a 12-cylinder 38L diesel engine with turbocharged, water/air-cooled aspiration, Cummins PT fuel pump, EFC electronic governor and a 1500 RPM rated speed at 50Hz.
Q: What is the Cummins KTA38-G2B engine output at 50Hz?
A: The Cummins KTA38-G2B provides 711kW rated engine output and 790kW standby engine output at 1500 RPM and 50Hz. These are engine output ratings, while the GENLITEC POWER generator set is rated at 640kW/800kVA prime and 700kW/880kVA standby.
Q: What is the fuel tank capacity and fuel consumption?
A: The standard GPC800 configuration is equipped with a 1200L fuel tank. Fuel consumption is approximately 142kg/H at 100% prime load, 109kg/H at 75% load, 77kg/H at 50% load and 45kg/H at 25% load.
Q: What voltage and frequency can the GPC800 generator provide?
A: The standard configuration is 50Hz, three-phase, four-wire output. Available voltage configurations include 220/380V, 230/400V and 240/415V, depending on the selected alternator configuration and project requirements.
Q: What is the difference between the GPC800D5 and GPC800S5?
A: Both models use the same Cummins KTA38-G2B engine and generator rating. The GPC800D5 is an open type generator set designed mainly for generator rooms and installations with suitable ventilation, while the GPC800S5 uses a weatherproof sound-attenuated enclosure for outdoor and noise-sensitive applications.
Q: Is the GPC800 suitable for prime power applications?
A: Yes. The GPC800 series is rated at 640kW/800kVA prime power and is suitable for long-duration power applications when operated within the specified load profile, environmental conditions and maintenance requirements.
Q: Can the GPC800 be configured for automatic operation or parallel operation?
A: Yes. ATS, automatic start and stop, synchronization and paralleling systems, remote monitoring, water-jacket heaters and other options can be configured according to the project requirements.
Q: Where can the 800kVA Cummins generator be used?
A: The GPC800 series is suitable for factories, commercial buildings, construction sites, mining projects, infrastructure, telecommunications, data centers and other applications requiring reliable prime or standby power.
Q: What warranty is provided for the GPC800 series?
A: The standard warranty is 12 months or 1000 working hours, whichever comes first.