?> 50Hz 1000kW 1250kVA Perkins 4012-46TWG2A Diesel Generator

50Hz 1000kW 1250kVA Diesel Generator with Perkins 4012-46TWG2A Engine

50Hz 1000kW 1250kVA Diesel Generator with Perkins 4012-46TWG2A Engine - Image 1
  • 50Hz 1000kW 1250kVA Diesel Generator with Perkins 4012-46TWG2A Engine - Image 1
  • 50Hz 1000kW 1250kVA Diesel Generator with Perkins 4012-46TWG2A Engine - Image 2

Short Description

GENLITEC GPP1250D5 / GPP1250S5 diesel generator set powered by Perkins 4012-46TWG2A, with prime power 1000KW/1250KVA, standby power 1100KW/1375KVA.

  • ModelGPP1250S5
  • Prime Power (PRP)1000kW/1250kVA
  • Standby Power (ESP)1100kW/1375kVA
  • Engine4012-46TWG2A
  • Fuel consumption (100%)259L/H
Share

Product Details

Product Tags

50Hz 1000KW 1250KVA Diesel Generator with Perkins 4012-46TWG2A Diesel Engine

Introduction

The GENLITEC POWER GPP1250D5 / GPP1250S5 is a 1250 kVA diesel generator set designed for reliable prime, standby and backup power applications. With a rated output of 1000KW/1250KVA prime power and 1100KW/1375KVA standby power, this 50Hz diesel generator provides dependable three-phase power for commercial, industrial, construction, agricultural, telecommunications, data center and other demanding applications.

Powered by a Perkins 4012-46TWG2A turbocharged diesel engine with water/air cooling, the GPP1250D5 / GPP1250S5 combines a 12-cylinder 45.842L engine with electronic governing, direct injection and high power density. The generator set is available in both open type and silent type versions, with rated voltage options of 220/380V, 230/400V and 240/415V. A 1000L standard fuel tank is provided, while optional ATS panel, synchronization system, remote monitoring system and other accessories are available for different project requirements. This 1000KW/1250KVA Perkins diesel generator is suitable for prime power, emergency standby power and backup power applications where reliable electricity supply is required.

Generator Set

Open Type Model GPP1250D5
Silent Type Model GPP1250S5
Phase & Wires 3 Phase, 4 Wires
Power Factor 0.8
Frequency 50Hz
Prime Power 1000KW/1250KVA
Standby Power 1100KW/1375KVA
Rated Voltage 220/380V, 230/400V, 240/415V
Fuel Tank Capacity 1000L

Diesel Engine

Engine Model PERKINS 4012-46TWG2A
Cylinder Number 12-V
Aspiration System Turbocharged, Water/Air Cooling
Cooling Method Water Cooled with Radiator
Governor Type Electronic
Combustion System Direct Injection
Bore x Stroke 160 x 190 mm
Compression Ratio 13.6:1
Displacement 45.842L
Rated Power 1113KW
Standby Power 1224KW
Oil Consumption 4g/kW.h
Coolant Capacity 201L
Oil Capacity 177L
Electric Starting System DC 24V

Fuel Consumption

110% Prime Load 288L/H
100% Prime Load 259L/H
75% Prime Load 196L/H
50% Prime Load 143L/H

Alternator

Number of Phase 3
Rated Power 1000KW/1250KVA
Frequency 50Hz
Power Factor 0.8
Poles 4
Temperature Rise 125K
Terminals 6/12
Insulation Class H
Ambient Temperature 40℃
IP Rating IP23
Excitation System Self-Excited
Bearing Single Bearing
Coating Vacuum Impregnation
Voltage Regulator A.V.R
Coupling Flexible Disc

Control Panel

○ Emergency stop button ○ Main circuit breaker
○ Float battery charger ○ Manual/Auto start control panel
○ Fuel level meter ○ Controller power switch
○ Alarm buzzer

Sound Attenuated Enclosure

○ Weatherproof sound-attenuated enclosure with internal exhaust silencer

○ Corrosion-resistant construction for outdoor installation

○ Available for GPP1250S5 silent type generator set

Options

○ ATS for automatic start and stop when utility power fails or returns

○ Synchronization System

○ Remote monitoring system

○ Water-Jacket Heater

○ Other Heaters

Applications

The GENLITEC POWER 1000KW/1250KVA diesel generator set is suitable for a wide range of prime, standby and backup power applications, including:

○ Commercial and office buildings

○ Industrial facilities

○ Construction and job sites

○ Agricultural and rural facilities

○ Telecommunication and remote sites

○ Data centers and critical infrastructure

○ Emergency and standby power systems

Why Choose GENLITEC POWER

GENLITEC POWER GPP1250D5 / GPP1250S5 diesel generator sets combine a Perkins 4012-46TWG2A engine with a high-power generator set configuration for dependable prime and standby power.

○ Perkins 4012-46TWG2A diesel engine for reliable high-power generation

○ 1000KW/1250KVA prime power and 1100KW/1375KVA standby power

○ 45.842L twelve-cylinder engine with turbocharged water/air cooling

○ 1000KW/1250KVA alternator for high-power generator applications

○ Multiple voltage configurations available

○ Open and silent type configurations available

○ Electronic engine governing for precise engine speed and performance management

○ Suitable for commercial, industrial, data center and backup power applications

○ Factory-direct supply with customized generator set solutions

For more information, please visit the GENLITEC POWER® Why Choose GENLITEC POWER page.

Warranty

GENLITEC POWER provides a standard warranty of 12 months or 1000 working hours, whichever comes first. For details, please refer to the GENLITEC POWER® Warranty Policy.

FAQ

Q: What is the rated power of the GPP1250D5 / GPP1250S5 generator set?
A: The generator set provides 1000KW/1250KVA prime power and 1100KW/1375KVA standby power at 50Hz.
Q: Which diesel engine is used in the GPP1250D5 / GPP1250S5?
A: The generator set is powered by a Perkins 4012-46TWG2A twelve-cylinder, 45.842L turbocharged diesel engine with electronic governing and direct injection.
Q: What voltage configurations are available?
A: The available rated voltage configurations are 220/380V, 230/400V and 240/415V.
Q: What is the difference between the open and silent type generator sets?
A: The GPP1250D5 is the open type model, while the GPP1250S5 is equipped with a sound-attenuated enclosure for applications where lower noise levels and weather protection are required.
Q: What is the fuel consumption of the GPP1250D5 / GPP1250S5?
A: The fuel consumption is approximately 288 L/H at 110% prime load, 259 L/H at 100% prime load, 196 L/H at 75% prime load and 143 L/H at 50% prime load.
Q: What is the fuel tank capacity?
A: The standard fuel tank capacity is 1000L. Larger fuel tanks are available as optional configurations for extended operating time.
Q: What is the frequency and rated speed of the generator set?
A: The generator set operates at 50Hz. The engine is designed for operation at the standard 1500 RPM speed for 50Hz generator applications.
Q: How many cylinders does the Perkins 4012-46TWG2A engine have?
A: The Perkins 4012-46TWG2A is a 12-cylinder V-type diesel engine with a 45.842L displacement.
Q: What are the bore and stroke of the Perkins 4012-46TWG2A engine?
A: The engine has a bore of 160 mm and a stroke of 190 mm, with a compression ratio of 13.6:1.
Q: What are the engine oil and coolant capacities?
A: The Perkins 4012-46TWG2A has an oil capacity of approximately 180L and a coolant capacity of approximately 201L.
Q: What is the warranty period for the GPP1250D5 / GPP1250S5?
A: GENLITEC POWER provides a standard warranty of 12 months or 1000 working hours, whichever comes first.

  • Previous: 60Hz 800kW 1000kVA Diesel Generator with Perkins 4008TAG2 Engine
  • Next: 50Hz 360kW 450kVA Diesel Generator with Cummins QSZ13-G5 Engine