?> 50Hz 400kW 500kVA Perkins 2506C-E15TAG2 Diesel Generator

50Hz 400kW 500kVA Diesel Generator with Perkins 2506C-E15TAG2 Engine

50Hz 400kW 500kVA Diesel Generator with Perkins 2506C-E15TAG2 Engine - Image 1
  • 50Hz 400kW 500kVA Diesel Generator with Perkins 2506C-E15TAG2 Engine - Image 1
  • 50Hz 400kW 500kVA Diesel Generator with Perkins 2506C-E15TAG2 Engine - Image 2
  • 50Hz 400kW 500kVA Diesel Generator with Perkins 2506C-E15TAG2 Engine - Image 3
  • 50Hz 400kW 500kVA Diesel Generator with Perkins 2506C-E15TAG2 Engine - Image 4

Short Description

GENLITEC POWER GP500D5/GPP500S5 diesel generator set powered by original Perkins 2506C-E15TAG2, with prime power 400KW/500KVA, standby power 440KW/550KVA.

  • ModelGPP500S5
  • Prime Power (PRP)400kW/500kVA
  • Standby Power (ESP)440kW/550kVA
  • Engine2506C-E15TAG2
  • Fuel consumption (100%)106L/H
Share

Product Details

Product Tags

50Hz 400KW 500KVA Diesel Generator with Perkins 2506C-E15TAG2 Diesel Engine

Introduction

The GENLITEC POWER GPP500D5 / GPP500S5 is a 500 kVA diesel generator set designed for reliable prime, standby and backup power applications. With a rated output of 400KW/500KVA prime power and 440KW/550KVA standby power, this 50Hz diesel generator operates at 1500 RPM and provides dependable three-phase power for commercial, industrial, construction, agricultural, telecommunications and other demanding applications.

Powered by a Perkins 2506C-E15TAG2 turbocharged and air-to-air charge cooled diesel engine, the GPP500D5 / GPP500S5 combines a 15.2L six-cylinder engine with full-authority electronic engine control, high power density and efficient fuel consumption. The generator set is available in both open type and silent type versions, with rated voltage options of 220/380V, 230/400V and 240/415V. A 750L standard fuel tank is provided, while optional 12-hour, 24-hour and 48-hour fuel tanks, ATS, trailer, remote monitoring system and power sockets are available for different project requirements. This 400KW/500KVA Perkins diesel generator is suitable for prime power, emergency standby power and backup power applications where reliable and efficient electricity supply is required.

Generator Set

Open Type Model GPP500D5
Silent Type Model GPP500S5
Frequency 50Hz
Phase & Wires 3 Phase, 4 Wires
Power Factor 0.8
Prime Power 400KW/500KVA
Standby Power 440KW/550KVA
Rated Voltage 220/380V; 230/400V; 240/415V
Rated Speed 1500 RPM
Fuel Tank Capacity 750L

Diesel Engine

Engine Model Perkins 2506C-E15TAG2
Cylinder Number 6
Cylinder Arrangement Vertical In-line
Cycle 4 Stroke
Aspiration System Turbocharged and Air-to-Air Charge Cooled
Cooling Method Liquid Cooled
Governor Type Electronic
Bore x Stroke 137 x 171 mm
Compression Ratio 16.0:1
Rated Speed 1500 RPM
Displacement 15.2L
Gross Engine Power - Prime 451KW
Gross Engine Power - Standby 495KW
Net Engine Power - Prime 435KW
Net Engine Power - Standby 478KW
Combustion System Direct Injection
Coolant Capacity Approximately 58L
Oil Capacity Approximately 62L
Electric Starting System DC 24V

Fuel Consumption

110% Prime Load 114L/H
100% Prime Load 106L/H
75% Prime Load 81L/H
50% Prime Load 55L/H

Alternator

Number of Phase 3
Rated Power 400KW/500KVA
Frequency 50Hz
Power Factor 0.8
Poles 4
Temperature Rise 125K
Terminals 6/12
Insulation Class H
Ambient Temperature 40℃
IP Rating IP23
Excitation System Self-Excited
Bearing Single Bearing
Coating Vacuum Impregnation
Voltage Regulator A.V.R
Coupling Flexible Disc

Control Panel

○ Emergency stop button ○ Main circuit breaker
○ Float battery charger ○ Manual/Auto start control panel
○ Fuel level meter ○ Controller power switch
○ Alarm buzzer

Sound Attenuated Enclosure

○ Weatherproof sound-attenuated enclosure with internal exhaust silencer

○ Corrosion-resistant construction for outdoor installation

○ Available for GPP500S5 silent type generator set

Options

○ ATS for automatic start and stop when utility power fails or returns

○ Synchronization System

○ Remote monitoring system

○ Water-Jacket Heater

○ Other Heaters

Applications

The GENLITEC POWER 400KW/500KVA diesel generator set is suitable for a wide range of prime, standby and backup power applications, including:

○ Commercial and office buildings

○ Industrial facilities

○ Construction and job sites

○ Agricultural and rural facilities

○ Telecommunication and remote sites

○ Emergency and standby power systems

Why Choose GENLITEC POWER

GENLITEC POWER GPP500D5 / GPP500S5 diesel generator sets combine a Perkins 2506C-E15TAG2 engine with a high-power generator set configuration for dependable prime and standby power.

○ Perkins 2506C-E15TAG2 diesel engine for reliable high-power generation

○ 400KW/500KVA prime power and 440KW/550KVA standby power

○ Multiple voltage configurations available

○ Open and silent type configurations available

○ Electronic engine control for precise engine speed and performance management

○ Suitable for commercial, industrial and backup power applications

○ Factory-direct supply with customized generator set solutions

For more information, please visit the GENLITEC POWER® Why Choose GENLITEC POWER page.

Warranty

GENLITEC POWER provides a standard warranty of 12 months or 1000 working hours, whichever comes first. For details, please refer to the GENLITEC POWER® Warranty Policy.

FAQ

Q: What is the rated power of the GPP500D5 / GPP500S5 generator set?
A: The generator set provides 400KW/500KVA prime power and 440KW/550KVA standby power at 50Hz and 1500 RPM.
Q: Which diesel engine is used in the GPP500D5 / GPP500S5?
A: The generator set is powered by a Perkins 2506C-E15TAG2 six-cylinder, 15.2L turbocharged and air-to-air charge cooled diesel engine with electronic engine control.
Q: What voltage configurations are available?
A: The available rated voltage configurations are 220/380V, 230/400V and 240/415V.
Q: What is the difference between the open and silent type generator sets?
A: The GPP500D5 is the open type model, while the GPP500S5 is equipped with a sound-attenuated enclosure for applications where lower noise levels and weather protection are required.
Q: What is the fuel consumption of the GPP500D5 / GPP500S5?
A: Based on Perkins 2506C-E15TAG2 fuel consumption data at 1500 RPM, the fuel consumption is approximately 114 L/H at standby power, 106 L/H at 100% prime load, 81 L/H at 75% prime load and 55 L/H at 50% prime load.
Q: What is the fuel tank capacity?
A: The standard fuel tank capacity is 750L. Larger fuel tanks are available as optional configurations for extended operating time.
Q: What is the frequency and rated speed of the generator set?
A: The generator set operates at 50Hz with a rated engine speed of 1500 RPM.
Q: How many cylinders does the Perkins 2506C-E15TAG2 engine have?
A: The Perkins 2506C-E15TAG2 is a six-cylinder vertical in-line diesel engine with a 15.2L displacement.
Q: What are the bore and stroke of the Perkins 2506C-E15TAG2 engine?
A: The engine has a bore of 137 mm and a stroke of 171 mm, with a compression ratio of 16.0:1.
Q: What is the warranty period for the GPP500D5 / GPP500S5?
A: GENLITEC POWER provides a standard warranty of 12 months or 1000 working hours, whichever comes first.

  • Previous: 60Hz 320kW 400kVA Diesel Generator with Perkins 2206C-E13TAG2 Engine
  • Next: 50Hz 220kW 275kVA Diesel Generator with Cummins NTA855-G1A Engine

  • Related Products