?> 50Hz 180kW 225kVA Perkins 1206A-E70TTAG2 Diesel Generator

50Hz 180kW 225kVA Diesel Generator with Perkins 1206A-E70TTAG2 Engine

50Hz 180kW 225kVA Diesel Generator with Perkins 1206A-E70TTAG2 Engine - Image 1
  • 50Hz 180kW 225kVA Diesel Generator with Perkins 1206A-E70TTAG2 Engine - Image 1
  • 50Hz 180kW 225kVA Diesel Generator with Perkins 1206A-E70TTAG2 Engine - Image 2

Short Description

GENLITEC GPP225D5/GPP225S5 225kVA/180kW 50Hz diesel generators with Perkins 1206A-E70TTAG2 engine for reliable prime and standby power.

  • ModelGPP225S5
  • Prime Power (PRP)180kW/225kVA
  • Standby Power (ESP)200kW/250kVA
  • Engine1206A-E70TTAG2
  • Fuel consumption (100%)51L/H
Share

Product Details

Product Tags

50Hz 180KW 225KVA Diesel Generator with Perkins 1206A-E70TTAG2 Diesel Engine

Introduction

The GENLITEC POWER GPP225D5 / GPP225S5 is a 225 kVA diesel generator set designed for reliable prime, standby and backup power applications. With a rated output of 180KW/225KVA prime power and 200KW/250KVA standby power, this 50Hz diesel generator operates at 1500 RPM and provides dependable three-phase power for commercial, industrial, construction, agricultural, telecommunications and other demanding applications.

Powered by a Perkins 1206A-E70TTAG2 turbocharged aftercooled diesel engine, the GPP225D5 / GPP225S5 combines a 7.01L six-cylinder engine with electronic governing, practical power output and efficient fuel consumption. The generator set is available in both open type and silent type versions, with rated voltage options of 220/380V, 230/400V and 240/415V. A 340L standard fuel tank is provided, while optional 12-hour, 24-hour and 48-hour fuel tanks, ATS, trailer, remote monitoring system and power sockets are available for different project requirements. This 180KW/225KVA Perkins diesel generator is suitable for prime power, emergency standby power and backup power applications where reliable and economical electricity supply is required.

Generator Set

Open Type Model GPP225D5
Silent Type Model GPP225S5
Frequency 50Hz
Phase & Wires 3 Phase, 4 Wires
Power Factor 0.8
Prime Power 180KW/225KVA
Standby Power 200KW/250KVA
Rated Voltage 220/380V; 230/400V; 240/415V
Rated Speed 1500 RPM
Fuel Tank Capacity 340L

Diesel Engine

Engine Model Perkins 1206A-E70TTAG2
Cylinder Number 6
Cylinder Arrangement Vertical In-line
Cycle 4 Stroke
Aspiration System Twin Turbocharged Aftercooled
Cooling Method Liquid Cooled
Governor Type Electronic
Bore x Stroke 105 x 135 mm
Compression Ratio 15.8:1
Rated Speed 1500 RPM
Displacement 7.01L
Rated Power 204.2KW
Standby Power 226.1KW
Combustion System Direct Injection
Oil Capacity 16L
Coolant Capacity 25L
Electric Starting System DC 12V

Fuel Consumption

100% Prime Load 51.0L/H
75% Prime Load 38.0L/H
50% Prime Load 25.5L/H
25% Prime Load 14.0L/H

Alternator

Number of Phase 3
Rated Power 180KW/225KVA
Frequency 50Hz
Power Factor 0.8
Poles 4
Temperature Rise 125K
Terminals 12
Insulation Class H Class
Ambient Temperature 40℃
IP Rating IP23
Excitation System Self-Excited
Bearing Single Bearing
Coating Vacuum Impregnation
Voltage Regulator A.V.R
Coupling Flexible Disc

Control Panel

○ Emergency stop button ○ Main circuit breaker
○ Float battery charger ○ Manual/Auto start control panel
○ Fuel level meter ○ Controller power switch
○ Alarm buzzer

Sound Attenuated Enclosure

○ Weatherproof sound-attenuated enclosure with internal exhaust silencer

○ Corrosion-resistant construction for outdoor installation

○ Available for GPP225S5 silent type generator set

Options

○ ATS for automatic start and stop when utility power fails or returns

○ Single axle trailer

○ 12-hour fuel tank

○ 24-hour fuel tank

○ 48-hour fuel tank

○ Remote monitoring system

○ Power sockets, including CEE or AUS standards

Applications

The GENLITEC POWER 180KW/225KVA diesel generator set is suitable for a wide range of prime, standby and backup power applications, including:

○ Commercial and office buildings

○ Industrial facilities

○ Construction and job sites

○ Agricultural and rural facilities

○ Telecommunication and remote sites

○ Emergency and standby power systems

Why Choose GENLITEC POWER

GENLITEC POWER GPP225D5 / GPP225S5 diesel generator sets combine a Perkins 1206A-E70TTAG2 engine with a practical generator set configuration for dependable prime and standby power.

○ Perkins 1206A-E70TTAG2 diesel engine for reliable power generation

○ 180KW/225KVA prime power and 200KW/250KVA standby power

○ Multiple voltage configurations available

○ Open and silent type configurations available

○ Electronic governor for precise engine speed control

○ Suitable for commercial, industrial and backup power applications

○ Factory-direct supply with customized generator set solutions

For more information, please visit the GENLITEC POWER® Why Choose GENLITEC POWER page.

Warranty

GENLITEC POWER provides a standard warranty of 12 months or 1000 working hours, whichever comes first. For details, please refer to the GENLITEC POWER® Warranty Policy.

FAQ

Q: What is the rated power of the GPP225D5 / GPP225S5 generator set?
A: The generator set provides 180KW/225KVA prime power and 200KW/250KVA standby power.
Q: Which diesel engine is used in the GPP225D5 / GPP225S5?
A: The generator set is powered by a Perkins 1206A-E70TTAG2 twin turbocharged aftercooled diesel engine with electronic governing.
Q: What voltage configurations are available?
A: The available rated voltage configurations are 220/380V, 230/400V and 240/415V.
Q: What is the difference between the open and silent type generator sets?
A: The GPP225D5 is the open type model, while the GPP225S5 is equipped with a sound-attenuated enclosure for applications where lower noise levels and weather protection are required.
Q: What is the fuel consumption of the GPP225D5 / GPP225S5?
A: The Perkins 1206A-E70TTAG2 engine has a fuel consumption of approximately 51.0 L/H at 100% prime load, 38.0 L/H at 75% prime load, 25.5 L/H at 50% prime load and 14.0 L/H at 25% prime load.
Q: What is the fuel tank capacity?
A: The standard fuel tank capacity is 340L. Larger fuel tanks are available as optional configurations for extended operating time.
Q: What is the frequency and rated speed of the generator set?
A: The generator set operates at 50Hz with a rated engine speed of 1500 RPM.
Q: How many cylinders does the Perkins 1206A-E70TTAG2 engine have?
A: The Perkins 1206A-E70TTAG2 is a six-cylinder diesel engine with a 7.01L displacement.
Q: What are the bore and stroke of the Perkins 1206A-E70TTAG2 engine?
A: The engine has a bore of 105 mm and a stroke of 135 mm, with a compression ratio of 15.8:1.
Q: What is the warranty period for the GPP225D5 / GPP225S5?
A: GENLITEC POWER provides a standard warranty of 12 months or 1000 working hours, whichever comes first.

  • Previous: 8m Hydraulic 4 x 400W LED Light Tower with Quanchai QC380D Engine
  • Next: 280KVA Perkins Diesel Generator-60Hz

  • Related Products