50Hz 240kW 300kVA Diesel Generator with Perkins 1706A-E93TAG1 Engine

50Hz 240kW 300kVA Diesel Generator with Perkins 1706A-E93TAG1 Engine - Image 1
  • 50Hz 240kW 300kVA Diesel Generator with Perkins 1706A-E93TAG1 Engine - Image 1
  • 50Hz 240kW 300kVA Diesel Generator with Perkins 1706A-E93TAG1 Engine - Image 2
  • 50Hz 240kW 300kVA Diesel Generator with Perkins 1706A-E93TAG1 Engine - Image 3
  • 50Hz 240kW 300kVA Diesel Generator with Perkins 1706A-E93TAG1 Engine - Image 4

Short Description

GENLITEC GP300D5-II/GPP300S5-II diesel generator set powered by original Perkins 1706A-E93TAG1, with prime power 240KW/300KVA, standby power 264KW/330KVA.

  • ModelGPP300D5-II | GPP300S5-II
  • Frequency50Hz
  • Prime Power240KW/300KVA
  • Standby Power264KW/330KVA
  • EnginePerkins 1706A-E93TAG1
  • Fuel Consumption (100% Load)62.5L/H
  • MOQ1 Set

Product Details

Product Tags

50Hz 240KW 300KVA Diesel Generator with Perkins 1706A-E93TAG1 Diesel Engine

Introduction

The GENLITEC POWER GPP300D5-II / GPP300S5-II is a 300 kVA diesel generator set designed for reliable prime, standby and backup power applications. With a rated output of 240KW/300KVA prime power and 264KW/330KVA standby power, this 50Hz diesel generator operates at 1500 RPM and provides dependable three-phase power for commercial, industrial, construction, agricultural, telecommunications and other demanding applications.

Powered by a Perkins 1706A-E93TAG1 turbocharged aftercooled diesel engine, the GPP300D5-II / GPP300S5-II combines a 9.29L six-cylinder engine with electronic governing, practical power output and efficient fuel consumption. The generator set is available in both open type and silent type versions, with rated voltage options of 220/380V, 230/400V and 240/415V. A 450L standard fuel tank is provided, while optional 12-hour, 24-hour fuel tanks, ATS, trailer, remote monitoring system and synchronization system are available for different project requirements. This 240KW/300KVA Perkins diesel generator is suitable for prime power, emergency standby power and backup power applications where reliable and economical electricity supply is required.

Generator Set

Open Type Model GPP300D5-II
Silent Type Model GPP300S5-II
Frequency 50Hz
Phase & Wires 3 Phase, 4 Wires
Power Factor 0.8
Prime Power 240KW/300KVA
Standby Power 264KW/330KVA
Rated Voltage 220/380V; 230/400V; 240/415V
Rated Speed 1500 RPM
Fuel Tank Capacity 450L

Diesel Engine

Engine Model Perkins 1706A-E93TAG1
Cylinder Number 6
Cylinder Arrangement Vertical In-line
Cycle 4 Stroke
Aspiration System Turbocharged Aftercooled
Cooling Method Water Cooled
Governor Type Electronic
Bore x Stroke 115 x 149 mm
Compression Ratio 16.5:1
Rated Speed 1500 RPM
Displacement 9.29L
Rated Power 267KW
Standby Power 295KW
Combustion System Direct Injection
Oil Capacity 26-30L
Coolant Capacity 33L
Electric Starting System DC 24V

Fuel Consumption

100% Prime Load 62.5L/H
75% Prime Load 47.9L/H
50% Prime Load 33.7L/H
25% Prime Load 19.4L/H

Alternator

Number of Phase 3
Rated Power 240KW/300KVA
Frequency 50Hz
Power Factor 0.8
Poles 4
Temperature Rise 125K
Terminals 12
Insulation Class H Class
Ambient Temperature 40℃
IP Rating IP23
Excitation System Self-Excited
Bearing Single Bearing
Coating Vacuum Impregnation
Voltage Regulator A.V.R
Coupling Flexible Disc

Control Panel

○ Emergency stop button ○ Main circuit breaker
○ Float battery charger ○ Manual/Auto start control panel
○ Fuel level meter ○ Controller power switch
○ Alarm buzzer

Sound Attenuated Enclosure

○ Weatherproof sound-attenuated enclosure with internal exhaust silencer

○ Corrosion-resistant construction for outdoor installation

○ Available for GPP300S5-II silent type generator set

Options

○ ATS for automatic start and stop when utility power fails or returns

○ Double-axle trailer

○ 12-hour fuel tank

○ 24-hour fuel tank

○ Remote monitoring system

○ Synchronization system

Applications

The GENLITEC POWER 240KW/300KVA diesel generator set is suitable for a wide range of prime, standby and backup power applications, including:

○ Commercial and office buildings

○ Industrial facilities

○ Construction and job sites

○ Agricultural and rural facilities

○ Telecommunication and remote sites

○ Emergency and standby power systems

Why Choose GENLITEC POWER

GENLITEC POWER GPP300D5-II / GPP300S5-II diesel generator sets combine a Perkins 1706A-E93TAG1 engine with a practical generator set configuration for dependable prime and standby power.

○ Perkins 1706A-E93TAG1 diesel engine for reliable power generation

○ 240KW/300KVA prime power and 264KW/330KVA standby power

○ Multiple voltage configurations available

○ Open and silent type configurations available

○ Electronic governor for precise engine speed control

○ Suitable for commercial, industrial and backup power applications

○ Factory-direct supply with customized generator set solutions

For more information, please visit the GENLITEC POWER® Why Choose GENLITEC POWER page.

Warranty

GENLITEC POWER provides a standard warranty of 12 months or 1000 working hours, whichever comes first. For details, please refer to the GENLITEC POWER® Warranty Policy.

FAQ

Q: What is the rated power of the GPP300D5-II / GPP300S5-II generator set?
A: The generator set provides 240KW/300KVA prime power and 264KW/330KVA standby power.
Q: Which diesel engine is used in the GPP300D5-II / GPP300S5-II?
A: The generator set is powered by a Perkins 1706A-E93TAG1 turbocharged aftercooled diesel engine with electronic governing.
Q: What voltage configurations are available?
A: The available rated voltage configurations are 220/380V, 230/400V and 240/415V.
Q: What is the difference between the open and silent type generator sets?
A: The GPP300D5-II is the open type model, while the GPP300S5-II is equipped with a sound-attenuated enclosure for applications where lower noise levels and weather protection are required.
Q: What is the fuel consumption of the GPP300D5-II / GPP300S5-II?
A: The Perkins 1706A-E93TAG1 engine has a fuel consumption of approximately 56.6 L/H at 100% prime load, 47.3 L/H at 75% prime load, 33.3 L/H at 50% prime load and 19.4 L/H at 25% prime load.
Q: What is the fuel tank capacity?
A: The standard fuel tank capacity is 450L. Larger fuel tanks are available as optional configurations for extended operating time.
Q: What is the frequency and rated speed of the generator set?
A: The generator set operates at 50Hz with a rated engine speed of 1500 RPM.
Q: How many cylinders does the Perkins 1706A-E93TAG1 engine have?
A: The Perkins 1706A-E93TAG1 is a six-cylinder diesel engine with a 9.29L displacement.
Q: What are the bore and stroke of the Perkins 1706A-E93TAG1 engine?
A: The engine has a bore of 115 mm and a stroke of 149 mm, with a compression ratio of 16.5:1.
Q: What is the warranty period for the GPP300D5-II / GPP300S5-II?
A: GENLITEC POWER provides a standard warranty of 12 months or 1000 working hours, whichever comes first.

  • Previous: 50Hz 200kW 250kVA Diesel Generator with Cummins 6LTAA8.9-G2 Engine
  • Next: 60Hz 21kW 26kVA Diesel Generator with Kubota V2003-T-E2BG Engine