50Hz 400kW 500kVA Diesel Generator with Cummins QSZ13-G10 Engine
Short Description
GENLITEC POWER GPC500D5-I/GPC500S5-I diesel gensets with Cummins QSZ13-G3, 400kW/500kVA prime and 440kW/550kVA standby power.
- ModelGPC500D5-I | GPC500S5-I
- Frequency50Hz
- Prime Power400KW/500KVA
- Standby Power440KW/550KVA
- EngineCummins QSZ13-G10
- AlternatorStamford/Leroy Somer/Genlitec Power
- Fuel Consumption (100% Load)107L/H
- MOQ1 Set
Product Details
Product Tags
Introduction
The GENLITEC POWER® GPC500D5-I and GPC500S5-I are 500kVA Cummins diesel generator sets designed to provide reliable three-phase power for industrial, commercial, construction, mining, infrastructure and standby power applications. The generator sets are rated at 400kW/500kVA for prime power and 440kW/550kVA for standby power at 50Hz, with 1500 RPM operation.
Powered by the Cummins QSZ13-G10 six-cylinder, 13-liter diesel engine, the GPC500 series combines high engine capacity with a 400kW/500kVA alternator output. The Cummins QSZ13-G10 features turbocharged and charge air cooled technology, a Cummins XPI fuel system, electronic governor and water-cooled design. At 50Hz and 1500 RPM, the QSZ13-G10 provides approximately 463kW prime engine output and 509kW standby engine output, providing adequate engine capacity for the rated generator set output.
The GPC500 generator set is available in both open and silent configurations. The GPC500D5-I open type is suitable for generator rooms and installations where easy maintenance and ventilation are required, while the GPC500S5-I silent type features a weatherproof sound-attenuated enclosure for outdoor and noise-sensitive applications. A 750L fuel tank is provided for extended operating periods, while ATS, synchronization, remote monitoring and other options are available for different project requirements.
Generator Set
| Open Type Model | GPC500D5-I |
| Silent Type Model | GPC500S5-I |
| Prime Power | 400KW/500KVA |
| Standby Power | 440KW/550KVA |
| Phase & Wire | 3 Phase, 4 Wires |
| Power Factor | 0.8 |
| Frequency | 50Hz |
| Voltage | 220/380V, 230/400V, 240/415V |
| Fuel Tank Capacity | 750L |
Diesel Engine
| Engine Model | CUMMINS QSZ13-G10 |
| Cylinder Number | 6 |
| Aspiration System | Turbocharged, Charge Air Cooled |
| Cooling Method | Water Cooled |
| Governor Type | Electronic |
| Bore x Stroke | 130 x 163 mm |
| Compression Ratio | 17:1 |
| Rated Speed | 1500 RPM |
| Displacement | 13L |
| Prime Power | 463KW |
| Standby Power | 509KW |
| Fuel System | Cummins XPI |
| Electric Starting System | DC 24V |
Fuel Consumption
| 100% Prime Load | 107L/H |
| 75% Prime Load | 80L/H |
| 50% Prime Load | 54L/H |
| 25% Prime Load | 29L/H |
Alternator
| Number of Phase | 3 |
| Rated Power | 400KW/500KVA |
| Frequency | 50Hz |
| Power Factor | 0.8 |
| Poles | 4 |
| Temperature Rise | 125K |
| Terminals | 12 |
| Insulation Class | H Class |
| Ambient Temperature | 40℃ |
| IP Rating | IP23 |
| Excitation System | Self-Excited |
| Bearing | Single Bearing |
| Coating | Vacuum Impregnation |
| Voltage Regulator | A.V.R |
| Coupling | Flexible Disc |
Control Panel
| ○ Emergency stop button | ○ Main circuit breaker |
| ○ Float battery charger | ○ Manual/Auto start control panel |
| ○ Fuel level meter | ○ Controller power switch |
| ○ Alarm buzzer |
Sound Attenuated Enclosure
○ Weatherproof sound-attenuated enclosure with internal exhaust silencer
○ Corrosion-resistant construction for outdoor installation
○ Available for GPC500S5-I silent type generator set
Options
○ ATS for automatic start and stop when utility power fails or returns
○ 12-hour fuel tank
○ 24-hour fuel tank
○ Water-jacket heater
○ Other heaters
○ AREM & PMG
○ Synchronization System
○ Remote & Monitoring System
Applications
The GENLITEC POWER 400kW/500kVA Cummins diesel generator set is suitable for prime and standby power applications where stable and dependable power is required, including:
○ Commercial buildings and office complexes
○ Industrial facilities and manufacturing plants
○ Construction sites and infrastructure projects
○ Mining and heavy-duty applications
○ Telecommunication and remote facilities
○ Data centers and critical power systems
○ Emergency and standby power applications
Why Choose GENLITEC POWER
GENLITEC POWER combines established engine technology, carefully selected generator components and professional assembly to provide reliable diesel generator sets for demanding power applications. The GPC500 series uses the Cummins QSZ13-G10 engine and is configured to deliver 400kW/500kVA prime power with strong engine reserve capacity.
○ Genuine Cummins QSZ13-G10 diesel engine configuration
○ 400kW/500kVA prime power and 440kW/550kVA standby power
○ 13L six-cylinder turbocharged and charge air cooled diesel engine
○ Cummins XPI fuel system and electronic governor
○ Approximately 463kW prime and 509kW standby engine output at 50Hz
○ 750L fuel tank for extended operating periods
○ High-quality alternator with H Class insulation and IP23 protection
○ Open and silent configurations for different installation requirements
○ ATS, synchronization and remote monitoring options available
○ Professional manufacturing, testing and international export experience
For more information, please visit the GENLITEC POWER® Why Choose GENLITEC POWER page.
Warranty
GENLITEC POWER provides a standard warranty of 12 months or 1000 working hours, whichever comes first. For details, please refer to the GENLITEC POWER® Warranty Policy.