50Hz 460kW 575kVA Diesel Generator with Cummins KTAA19-G6 Engine

50Hz 460kW 575kVA Diesel Generator with Cummins KTAA19-G6 Engine - Image 1
  • 50Hz 460kW 575kVA Diesel Generator with Cummins KTAA19-G6 Engine - Image 1
  • 50Hz 460kW 575kVA Diesel Generator with Cummins KTAA19-G6 Engine - Image 2
  • 50Hz 460kW 575kVA Diesel Generator with Cummins KTAA19-G6 Engine - Image 3
  • 50Hz 460kW 575kVA Diesel Generator with Cummins KTAA19-G6 Engine - Image 4

Short Description

GENLITEC POWER GPC575D5/GPC575S5 575kVA diesel generator powered by CUMMINS KTAA19-G6, delivering 460kW prime and 520kW standby power.

  • ModelGPC575D5 | GPC575S5
  • Frequency50Hz
  • Prime Power460KW/575KVA
  • Standby Power520KW/650KVA
  • EngineCummins KTAA19-G6
  • AlternatorStamford/Leroy Somer/Genlitec Power
  • Fuel Consumption (100% Load)112kg/H
  • MOQ1 Set

Product Details

Product Tags

575kVA Cummins KTAA19-G6 diesel generator set GPC575D5 open type and GPC575S5 silent type

Introduction

The GENLITEC POWER® GPC575D5 and GPC575S5 are 575kVA Cummins diesel generator sets designed to provide reliable three-phase power for industrial, commercial, construction, mining, infrastructure and standby power applications. The generator sets are rated at 460kW/575kVA for prime power and 520kW/650kVA for standby power at 50Hz and 1500 RPM.

Powered by the Cummins KTAA19-G6 six-cylinder, 19-liter diesel engine, the GPC575 series combines proven heavy-duty engine technology with a 460kW/575kVA generator output. The KTAA19-G6 features a turbocharged and air-to-air cooled air intake system, Cummins PT fuel pump system, electronic governor and water-cooled design. With a rated engine power of 520kW at 1500 RPM, the engine provides sufficient power reserve for demanding generator applications.

The GPC575 generator set is available in both open and silent configurations. The GPC575D5 open type is suitable for generator rooms and installations where easy maintenance and ventilation are required, while the GPC575S5 silent type features a weatherproof sound-attenuated enclosure for outdoor and noise-sensitive applications. An 870L fuel tank is provided for extended operating periods, while ATS, synchronization, remote monitoring and other options are available for different project requirements.

Generator Set

Open Type Model GPC575D5
Silent Type Model GPC575S5
Prime Power 460KW/575KVA
Standby Power 520KW/650KVA
Phase & Wires 3 Phase, 4 Wires
Power Factor 0.8
Frequency 50Hz
Rated Voltage 220/380V, 230/400V, 240/415V
Fuel Tank Capacity 870L

Diesel Engine

Model CUMMINS KTAA19-G6
Cylinder Number 6
Aspiration System Turbocharged, Air to Air Cooled
Cooling Method Water Cooled
Governor Type Electronic
Bore x Stroke 159 x 159 mm
Compression Ratio 13.9:1
Rated Speed 1500RPM
Displacement 19L
Rated Power 520KW
Standby Power 570KW
Coolant Capacity 26.5L (Engine Only)
Oil Capacity 37.9L
Fuel System CUMMINS PT Pump
Electric Starting System DC 24V

Fuel Consumption (KG/H)

100% Prime Load 112 KG/H
75% Prime Load 83 KG/H
50% Prime Load 56 KG/H
25% Prime Load 32 KG/H

Alternator

Number of Phase 3
Rated Power 480KW/600KVA
Frequency 50Hz
Power Factor 0.8
Poles 4
Temp. Rise 125K
Terminals 12
Insulation Class H Class
Ambient Temp. 40℃
IP Rating IP23
Excitation System Self-Excited
Bearing Single Bearing
Coating Vacuum Impregnation
Voltage Regulator A.V.R
Coupling Flexible Disc

Control Panel

○ Emergency stop button ○ Main circuit breaker
○ Float battery charger ○ Manual/Auto start control panel
○ Fuel level meter ○ Controller power switch
○ Alarm buzzer

Sound Attenuated Enclosure

○ Weatherproof sound-attenuated enclosure with internal exhaust silencer

○ Corrosion-resistant construction for outdoor installation

○ Available for GPC575S5 silent type generator set

Options

○ ATS for automatic start and stop when utility power fails or returns

○ 12-hour fuel tank

○ 24-hour fuel tank

○ Water-jacket heater

○ Other heaters

○ AREM & PMG

○ Synchronization System

○ Remote & Monitoring System

Applications

The GENLITEC POWER 460kW/575kVA Cummins KTAA19-G6 diesel generator set is suitable for prime and standby power applications where stable and dependable power is required, including:

○ Commercial buildings and office complexes

○ Industrial facilities and manufacturing plants

○ Construction sites and infrastructure projects

○ Mining and heavy-duty applications

○ Telecommunication and remote facilities

○ Data centers and critical power systems

○ Emergency and standby power applications

Why Choose GENLITEC POWER

GENLITEC POWER combines established engine technology, carefully selected generator components and professional assembly to provide reliable diesel generator sets for demanding power applications. The GPC575 series uses the Cummins KTAA19-G6 engine and is configured to deliver 460kW/575kVA prime power with sufficient engine reserve capacity.

○ Genuine Cummins KTAA19-G6 diesel engine configuration

○ 460kW/575kVA prime power and 520kW/650kVA standby power

○ 19L six-cylinder turbocharged and air-to-air cooled diesel engine

○ Cummins PT fuel pump system and electronic governor

○ 520kW rated engine power and 570kW standby engine power

○ 870L fuel tank for extended operating periods

○ High-quality alternator with H Class insulation and IP23 protection

○ Open and silent configurations for different installation requirements

○ ATS, synchronization and remote monitoring options available

○ Professional manufacturing, testing and international export experience

For more information, please visit the GENLITEC POWER® Why Choose GENLITEC POWER page.

Warranty

GENLITEC POWER provides a standard warranty of 12 months or 1000 working hours, whichever comes first. For details, please refer to the GENLITEC POWER® Warranty Policy.

Frequently Asked Questions

Q: What is the rated power of the GPC575 Cummins diesel generator set?
A: The GPC575D5 open type and GPC575S5 silent type are rated at 460kW/575kVA for prime power and 520kW/650kVA for standby power at 50Hz.
Q: Which Cummins engine is used in the 575kVA generator?
A: The GPC575 series is powered by the Cummins KTAA19-G6, a six-cylinder 19L diesel engine with turbocharged and air-to-air cooled technology, Cummins PT fuel pump system, electronic governor and 1500 RPM rated speed.
Q: What is the rated power of the Cummins KTAA19-G6 engine?
A: The Cummins KTAA19-G6 engine is rated at 520kW, with a standby power rating of 570kW at 1500 RPM. The GENLITEC POWER GPC575 generator set is rated at 460kW/575kVA prime and 520kW/650kVA standby.
Q: What is the fuel tank capacity and fuel consumption?
A: The standard GPC575 configuration is equipped with an 870L fuel tank. Fuel consumption is approximately 112KG/H at 100% prime load, 83KG/H at 75% load, 56KG/H at 50% load and 32KG/H at 25% load.
Q: What voltage and frequency can the GPC575 generator provide?
A: The standard configuration is 50Hz, three-phase, four-wire output. Available voltage configurations include 220/380V, 230/400V and 240/415V, depending on the selected alternator configuration and project requirements.
Q: What is the difference between the GPC575D5 and GPC575S5?
A: Both models use the same Cummins KTAA19-G6 engine and generator rating. The GPC575D5 is an open type generator set designed mainly for generator rooms and installations with suitable ventilation, while the GPC575S5 uses a weatherproof sound-attenuated enclosure for outdoor and noise-sensitive applications.
Q: Is the GPC575 suitable for prime power applications?
A: Yes. The GPC575 series is rated at 460kW/575kVA prime power and is suitable for long-duration power applications when operated within the specified load profile, environmental conditions and maintenance requirements.
Q: Can the GPC575 be configured for automatic operation or parallel operation?
A: Yes. ATS, automatic start and stop, synchronization and paralleling systems, remote monitoring, water-jacket heaters and other options can be configured according to the project requirements.
Q: Where can the 575kVA Cummins generator be used?
A: The GPC575 series is suitable for factories, commercial buildings, construction sites, mining projects, infrastructure, telecommunications, data centers and other applications requiring reliable prime or standby power.
Q: What warranty is provided for the GPC575 series?
A: The standard warranty is 12 months or 1000 working hours, whichever comes first.

  • Previous: 1000KVA Perkins Diesel Generator-60Hz
  • Next: 550KVA Deutz Diesel Generator-50Hz

  • Related Products