50Hz 800kW 1000kVA Diesel Generator with Cummins KTA38-G5 Engine

50Hz 800kW 1000kVA Diesel Generator with Cummins KTA38-G5 Engine - Image 1
  • 50Hz 800kW 1000kVA Diesel Generator with Cummins KTA38-G5 Engine - Image 1
  • 50Hz 800kW 1000kVA Diesel Generator with Cummins KTA38-G5 Engine - Image 2
  • 50Hz 800kW 1000kVA Diesel Generator with Cummins KTA38-G5 Engine - Image 3
  • 50Hz 800kW 1000kVA Diesel Generator with Cummins KTA38-G5 Engine - Image 4

Short Description

GENLITEC POWER GPC1000D5/GPC1000S5 Cummins diesel generator set powered by original CUMMINS KTA38-G5, with prime power 800KW/1000KVA.

  • ModelGPC1000D5 | GPC1000S5
  • Frequency50Hz
  • Prime Power800KW/1000KVA
  • Standby Power880KW/1100KVA
  • EngineCummins KTA38-G5
  • AlternatorStamford/Leroy Somer/Genlitec Power
  • Fuel Consumption (100% Load)178kg/H
  • MOQ1 Set

Product Details

Product Tags

1000kVA Cummins KTA38-G5 diesel generator set GPC1000D5 open type and GPC1000S5 silent type

Introduction

The GENLITEC POWER® GPC1000D5 and GPC1000S5 are 1000kVA Cummins diesel generator sets designed to provide reliable three-phase power for industrial, commercial, construction, mining, infrastructure and standby power applications. The generator sets are rated at 800kW/1000kVA for prime power and 880kW/1100kVA for standby power at 50Hz, with 1500 RPM operation.

Powered by the Cummins KTA38-G5 V-12, 38-liter diesel engine, the GPC1000 series combines high engine capacity with an 800kW/1000kVA alternator output. The Cummins KTA38-G5 features a turbocharged and water/air cooling system, Cummins PT Pump fuel system and EFC electronic governor. At 50Hz and 1500 RPM, the engine provides 880kW rated power and 970kW standby power, providing suitable engine capacity for the rated generator set output.

The GPC1000 generator set is available in both open and silent configurations. The GPC1000D5 open type is suitable for generator rooms and installations where easy maintenance and ventilation are required, while the GPC1000S5 silent type features a weatherproof sound-attenuated enclosure for outdoor and noise-sensitive applications. A 1000L fuel tank is provided for extended operating periods, while ATS, synchronization, remote monitoring and other options are available for different project requirements.

Generator Set

Open Type Model GPC1000D5
Silent Type Model GPC1000S5
Prime Power 800KW/1000KVA
Standby Power 880KW/1100KVA
Phase & Wire 3 Phase, 4 Wires
Power Factor 0.8
Frequency 50Hz
Rated Voltage 220/380V, 230/400V, 240/415V
Fuel Tank Capacity 1000L

Diesel Engine

Engine Model CUMMINS KTA38-G5
Cylinder Number V-12
Aspiration System Turbocharged, Water/Air Cooling
Cooling Method Water Cooled
Governor Type EFC Electronic
Bore x Stroke 159 x 159 mm
Compression Ratio 13.9:1
Rated Speed 1500 RPM
Displacement 38L
Rated Power 880KW
Standby Power 970KW
Coolant Capacity 258L
Oil Capacity 135L
Fuel System CUMMINS PT Pump
Electric Starting System DC 24V

Fuel Consumption

100% Prime Load 178kg/H
75% Prime Load 137kg/H
50% Prime Load 96kg/H
25% Prime Load 55kg/H

Alternator

Number of Phase 3
Rated Power 800KW/1000KVA
Frequency 50Hz
Power Factor 0.8
Poles 4
Temp. Rise 125K
Terminals 12
Insulation Class H
Ambient Temp. 40℃
IP Rating IP23
Excitation System Self-Excited
Bearing Single Bearing
Coating Vacuum Impregnation
Voltage Regulator A.V.R
Coupling Flexible Disc

Control Panel

○ Emergency stop button ○ Main circuit breaker
○ Float battery charger ○ Manual/Auto start control panel
○ Fuel level meter ○ Controller power switch
○ Alarm buzzer

Sound Attenuated Enclosure

○ Weatherproof sound-attenuated enclosure with internal exhaust silencer

○ Corrosion-resistant construction for outdoor installation

○ Available for GPC1000S5 silent type generator set

Options

○ ATS for automatic start and stop when utility power fails or returns

○ 20' Containerized canopy

○ Water-jacket heater

○ Other heaters

○ AREM & PMG

○ Synchronization System

○ Remote & Monitoring System

Applications

The GENLITEC POWER 800kW/1000kVA Cummins KTA38-G5 diesel generator set is suitable for prime and standby power applications where stable and dependable power is required, including:

○ Commercial buildings and office complexes

○ Industrial facilities and manufacturing plants

○ Construction sites and infrastructure projects

○ Mining and heavy-duty applications

○ Telecommunication and remote facilities

○ Data centers and critical power systems

○ Emergency and standby power applications

Why Choose GENLITEC POWER

GENLITEC POWER is a professional manufacturer and exporter of diesel generator sets and mobile lighting towers, providing reliable power equipment and customized power solutions to customers worldwide.

○ Established in 2016 with more than 10 years of experience in power equipment manufacturing and export

○ 66,000 m² manufacturing park with more than 7,000 m² assembly workshop

○ Annual production capacity of more than 2,500 generator sets

○ Products supplied to customers in more than 50 countries and regions worldwide

○ Professional engineering team providing customized power solutions for different applications and project requirements

○ Extensive experience with leading engine brands including Cummins, Perkins, Caterpillar, Yanmar, Kubota, Isuzu, Deutz, SDEC, Weichai and Yuchai

○ Alternator solutions from Stamford, Leroy Somer and GENLITEC to meet different performance and application requirements

○ Strict quality control and testing procedures throughout production and assembly

○ Complete power solutions including diesel generator sets, mobile lighting towers, ATS, synchronization and paralleling systems

○ Professional manufacturing, engineering and international export experience

For more information, please visit the GENLITEC POWER® Why Choose GENLITEC POWER page.

Warranty

GENLITEC POWER provides a standard warranty of 12 months or 1000 working hours, whichever comes first. For details, please refer to the GENLITEC POWER® Warranty Policy.

Frequently Asked Questions

Q: What is the rated power of the GPC1000 Cummins diesel generator set?
A: The GPC1000D5 open type and GPC1000S5 silent type are rated at 800kW/1000kVA for prime power and 880kW/1100kVA for standby power at 50Hz.
Q: Which Cummins engine is used in the 1000kVA generator?
A: The GPC1000 series is powered by the Cummins KTA38-G5, a V-12, 38L diesel engine with turbocharged and water/air cooling, Cummins PT Pump fuel system, EFC electronic governor and a 1500 RPM rated speed at 50Hz.
Q: What is the Cummins KTA38-G5 engine output at 50Hz?
A: The Cummins KTA38-G5 provides 880kW rated engine output and 970kW standby engine output at 1500 RPM and 50Hz. These are engine output ratings, while the GENLITEC POWER generator set is rated at 800kW/1000kVA prime and 880kW/1100kVA standby.
Q: What is the fuel tank capacity and fuel consumption?
A: The standard GPC1000 configuration is equipped with a 1000L fuel tank. Fuel consumption is 178kg/H at 100% prime load, 137kg/H at 75% load, 96kg/H at 50% load and 55kg/H at 25% load.
Q: What voltage and frequency can the GPC1000 generator provide?
A: The standard configuration is 50Hz, three-phase, four-wire output. Available voltage configurations include 220/380V, 230/400V and 240/415V, depending on the selected alternator configuration and project requirements.
Q: What is the difference between the GPC1000D5 and GPC1000S5?
A: Both models use the same Cummins KTA38-G5 engine and generator rating. The GPC1000D5 is an open type generator set designed mainly for generator rooms and installations with suitable ventilation, while the GPC1000S5 uses a weatherproof sound-attenuated enclosure for outdoor and noise-sensitive applications.
Q: Is the GPC1000 suitable for prime power applications?
A: Yes. The GPC1000 series is rated at 800kW/1000kVA prime power and is suitable for long-duration power applications when operated within the specified load profile, environmental conditions and maintenance requirements.
Q: Can the GPC1000 be configured for automatic operation or parallel operation?
A: Yes. ATS, automatic start and stop, synchronization and paralleling systems, remote monitoring, water-jacket heaters and other options can be configured according to project requirements.
Q: Where can the 1000kVA Cummins generator be used?
A: The GPC1000 series is suitable for factories, commercial buildings, construction sites, mining projects, infrastructure, telecommunications, data centers and other applications requiring reliable prime or standby power.
Q: What warranty is provided for the GPC1000 series?
A: The standard warranty is 12 months or 1000 working hours, whichever comes first.

  • Previous: 2050KVA Perkins Diesel Generator-50Hz
  • Next: 2250KVA Perkins Diesel Generator-50Hz