50Hz 280kW 350kVA Diesel Generator with Perkins 2206C-E13TAG2 Engine

50Hz 280kW 350kVA Diesel Generator with Perkins 2206C-E13TAG2 Engine - Image 1
  • 50Hz 280kW 350kVA Diesel Generator with Perkins 2206C-E13TAG2 Engine - Image 1
  • 50Hz 280kW 350kVA Diesel Generator with Perkins 2206C-E13TAG2 Engine - Image 2
  • 50Hz 280kW 350kVA Diesel Generator with Perkins 2206C-E13TAG2 Engine - Image 3
  • 50Hz 280kW 350kVA Diesel Generator with Perkins 2206C-E13TAG2 Engine - Image 4

Short Description

GENLITEC GP350D5-II/GPP350S5-II diesel generator set powered by original Perkins 2206C-E13TAG2, with prime power 280KW/350KVA, standby power 308KW/385KVA.

  • ModelGPP350D5-II | GPP350S5-II
  • Frequency50Hz
  • Prime Power280KW/350KVA
  • Standby Power308KW/385KVA
  • EnginePerkins 2206C-E13TAG2
  • Fuel Consumption (100% Load)75L/H
  • MOQ1 Set

Product Details

Product Tags

50Hz 280KW 350KVA Diesel Generator with Perkins 2206C-E13TAG2 Diesel Engine

Introduction

The GENLITEC POWER GPP350D5-II / GPP350S5-II is a 350 kVA diesel generator set designed for reliable prime, standby and backup power applications. With a rated output of 280KW/350KVA prime power and 308KW/385KVA standby power, this 50Hz diesel generator operates at 1500 RPM and provides dependable three-phase power for commercial, industrial, construction, agricultural, telecommunications and other demanding applications.

Powered by a Perkins 2206C-E13TAG2 turbocharged, air-to-air charge cooled diesel engine, the GPP350D5-II / GPP350S5-II combines a 12.5L six-cylinder engine with ECM engine control, high power density and efficient fuel consumption. The generator set is available in both open type and silent type versions, with rated voltage options of 220/380V, 230/400V and 240/415V. A 530L standard fuel tank is provided, while optional 12-hour, 24-hour and 48-hour fuel tanks, ATS, trailer, remote monitoring system and power sockets are available for different project requirements. This 280KW/350KVA Perkins diesel generator is suitable for prime power, emergency standby power and backup power applications where reliable and efficient electricity supply is required.

Generator Set

Open Type Model GPP350D5-II
Silent Type Model GPP350S5-II
Frequency 50Hz
Phase & Wires 3 Phase, 4 Wires
Power Factor 0.8
Prime Power 280KW/350KVA
Standby Power 308KW/385KVA
Rated Voltage 220/380V; 230/400V; 240/415V
Rated Speed 1500 RPM
Fuel Tank Capacity 530L

Diesel Engine

Engine Model Perkins 2206C-E13TAG2
Cylinder Number 6
Aspiration System Turbocharged, Air to Air Charge Cooled
Cooling Method Water Cooled
Governor Type ECM
Bore x Stroke 130 x 157 mm
Compression Ratio 16.3:1
Rated Speed 1500 RPM
Displacement 12.5L
Rated Power 324KW
Standby Power 368KW
Combustion System Direct Injection
Coolant Capacity 51.4L
Oil Capacity 40L
Electric Starting System DC 24V

Fuel Consumption

100% Standby Load 82L/H
100% Prime Load 75L/H
75% Prime Load 58L/H
50% Prime Load 40L/H

Alternator

Number of Phase 3
Rated Power 280KW/350KVA
Frequency 50Hz
Power Factor 0.8
Poles 4
Temperature Rise 125K
Terminals 6/12
Insulation Class H
Ambient Temperature 40℃
IP Rating IP23
Excitation System Self-Excited
Bearing Single Bearing
Coating Vacuum Impregnation
Voltage Regulator A.V.R
Coupling Flexible Disc

Control Panel

○ Emergency stop button ○ Main circuit breaker
○ Float battery charger ○ Manual/Auto start control panel
○ Fuel level meter ○ Controller power switch
○ Alarm buzzer

Sound Attenuated Enclosure

○ Weatherproof sound-attenuated enclosure with internal exhaust silencer

○ Corrosion-resistant construction for outdoor installation

○ Available for GPP350S5-II silent type generator set

Options

○ ATS for automatic start and stop when utility power fails or returns

○ Double axle trailer

○ 12-hour fuel tank

○ 24-hour fuel tank

○ 48-hour fuel tank

○ Remote monitoring system

Applications

The GENLITEC POWER 280KW/350KVA diesel generator set is suitable for a wide range of prime, standby and backup power applications, including:

○ Commercial and office buildings

○ Industrial facilities

○ Construction and job sites

○ Agricultural and rural facilities

○ Telecommunication and remote sites

○ Emergency and standby power systems

Why Choose GENLITEC POWER

GENLITEC POWER GPP350D5-II / GPP350S5-II diesel generator sets combine a Perkins 2206C-E13TAG2 engine with a high-power generator set configuration for dependable prime and standby power.

○ Perkins 2206C-E13TAG2 diesel engine for reliable high-power generation

○ 280KW/350KVA prime power and 308KW/385KVA standby power

○ Multiple voltage configurations available

○ Open and silent type configurations available

○ ECM engine control for precise engine speed and performance management

○ Suitable for commercial, industrial and backup power applications

○ Factory-direct supply with customized generator set solutions

For more information, please visit the GENLITEC POWER® Why Choose GENLITEC POWER page.

Warranty

GENLITEC POWER provides a standard warranty of 12 months or 1000 working hours, whichever comes first. For details, please refer to the GENLITEC POWER® Warranty Policy.

FAQ

Q: What is the rated power of the GPP350D5-II / GPP350S5-II generator set?
A: The generator set provides 280KW/350KVA prime power and 308KW/385KVA standby power.
Q: Which diesel engine is used in the GPP350D5-II / GPP350S5-II?
A: The generator set is powered by a Perkins 2206C-E13TAG2 six-cylinder turbocharged, air-to-air charge cooled diesel engine with ECM engine control.
Q: What voltage configurations are available?
A: The available rated voltage configurations are 220/380V, 230/400V and 240/415V.
Q: What is the difference between the open and silent type generator sets?
A: The GPP350D5-II is the open type model, while the GPP350S5-II is equipped with a sound-attenuated enclosure for applications where lower noise levels and weather protection are required.
Q: What is the fuel consumption of the GPP350D5-II / GPP350S5-II?
A: The estimated fuel consumption is approximately 75 L/H at 100% prime load, 58 L/H at 75% prime load and 40 L/H at 50% prime load. The specified 110% prime load fuel consumption is approximately 82 L/H.
Q: What is the fuel tank capacity?
A: The standard fuel tank capacity is 530L. Larger fuel tanks are available as optional configurations for extended operating time.
Q: What is the frequency and rated speed of the generator set?
A: The generator set operates at 50Hz with a rated engine speed of 1500 RPM.
Q: How many cylinders does the Perkins 2206C-E13TAG2 engine have?
A: The Perkins 2206C-E13TAG2 is a six-cylinder diesel engine with a 12.5L displacement.
Q: What are the bore and stroke of the Perkins 2206C-E13TAG2 engine?
A: The engine has a bore of 130 mm and a stroke of 157 mm, with a compression ratio of 16.3:1.
Q: What is the warranty period for the GPP350D5-II / GPP350S5-II?
A: GENLITEC POWER provides a standard warranty of 12 months or 1000 working hours, whichever comes first.

  • Previous: 450KVA Perkins Diesel Generator-60Hz
  • Next: 60Hz 17kW 21kVA Diesel Generator with Kubota V2203-E2BG Diesel Engine