?> 50Hz 600kW 750kVA Perkins 2806A-E18TTAG5 Diesel Generator

50Hz 600kW 750kVA Diesel Generator with Perkins 2806A-E18TTAG5 Engine

50Hz 600kW 750kVA Diesel Generator with Perkins 2806A-E18TTAG5 Engine - Image 1
  • 50Hz 600kW 750kVA Diesel Generator with Perkins 2806A-E18TTAG5 Engine - Image 1
  • 50Hz 600kW 750kVA Diesel Generator with Perkins 2806A-E18TTAG5 Engine - Image 2
  • 50Hz 600kW 750kVA Diesel Generator with Perkins 2806A-E18TTAG5 Engine - Image 3
  • 50Hz 600kW 750kVA Diesel Generator with Perkins 2806A-E18TTAG5 Engine - Image 4

Short Description

GENLITEC GPP750D5-I/GPP750S5-I diesel generator set powered by original Perkins 2806A-E18TTAG5, with prime power 600KW/750KVA, standby power 660KW/825KVA.

  • ModelGPP750S5-I
  • Prime Power (PRP)600kW/750kVA
  • Standby Power (ESP)660kW/825kVA
  • Engine2806A-E18TTAG5
  • Fuel consumption (100%)162L/H
Share

Product Details

Product Tags

50Hz 600KW 750KVA Diesel Generator with Perkins 2806A-E18TTAG5 Diesel Engine

Introduction

The GENLITEC POWER GPP750D5-I / GPP750S5-I is a 750 kVA diesel generator set designed for reliable prime, standby and backup power applications. With a rated output of 600KW/750KVA prime power and 660KW/825KVA standby power, this 50Hz diesel generator operates at 1500 RPM and provides dependable three-phase power for commercial, industrial, construction, agricultural, telecommunications and other demanding applications.

Powered by a Perkins 2806A-E18TTAG5 turbocharged and air-to-air charge cooled diesel engine, the GPP750D5-I / GPP750S5-I combines an 18.1L six-cylinder engine with electronic engine control, high power density and efficient fuel consumption. The generator set is available in both open type and silent type versions, with rated voltage options of 220/380V, 230/400V and 240/415V. A 1000L standard fuel tank is provided, while optional ATS, synchronization, remote monitoring, heaters and other accessories are available for different project requirements. This 600KW/750KVA Perkins diesel generator is suitable for prime power, emergency standby power and backup power applications where reliable electricity supply is required.

Generator Set

Open Type Model GPP750D5-I
Silent Type Model GPP750S5-I
Frequency 50Hz
Phase & Wires 3 Phase, 4 Wires
Power Factor 0.8
Prime Power 600KW/750KVA
Standby Power 660KW/825KVA
Rated Voltage 220/380V; 230/400V; 240/415V
Rated Speed 1500 RPM
Fuel Tank Capacity 1000L

Diesel Engine

Engine Model Perkins 2806A-E18TTAG5
Cylinder Number 6
Cylinder Arrangement Vertical In-line
Cycle 4 Stroke
Aspiration System Parallel Turbocharged and Air-to-Air Charge Cooled
Cooling Method Liquid Cooled
Governor Type Electronic
Bore x Stroke 145 x 183 mm
Compression Ratio 14:1
Rated Speed 1500 RPM
Displacement 18.1L
Gross Engine Power - Prime 671KW
Gross Engine Power - Standby 739KW
Net Engine Power - Prime 646KW
Net Engine Power - Standby 714KW
Combustion System Direct Injection
Coolant Capacity 110L
Oil Capacity 68L
Electric Starting System DC 24V

Fuel Consumption

Standby Power 180L/H
100% Prime Load 162L/H
75% Prime Load 118L/H
50% Prime Load 80L/H

Alternator

Number of Phase 3
Rated Power 600KW/750KVA
Frequency 50Hz
Power Factor 0.8
Poles 4
Temperature Rise 125K
Terminals 6/12
Insulation Class H
Ambient Temperature 40℃
IP Rating IP23
Excitation System Self-Excited
Bearing Single Bearing
Coating Vacuum Impregnation
Voltage Regulator A.V.R
Coupling Flexible Disc

Control Panel

○ Emergency stop button ○ Main circuit breaker
○ Float battery charger ○ Manual/Auto start control panel
○ Fuel level meter ○ Controller power switch
○ Alarm buzzer

Sound Attenuated Enclosure

○ Weatherproof sound-attenuated enclosure with internal exhaust silencer

○ Corrosion-resistant construction for outdoor installation

○ Available for GPP750S5-I silent type generator set

Options

○ ATS for automatic start and stop when utility power fails or returns

○ Synchronization System

○ Remote monitoring system

○ Water-Jacket Heater

○ Other Heaters

Applications

The GENLITEC POWER 600KW/750KVA diesel generator set is suitable for a wide range of prime, standby and backup power applications, including:

○ Commercial and office buildings

○ Industrial facilities

○ Construction and job sites

○ Agricultural and rural facilities

○ Telecommunication and remote sites

○ Emergency and standby power systems

Why Choose GENLITEC POWER

GENLITEC POWER GPP750D5-I / GPP750S5-I diesel generator sets combine a Perkins 2806A-E18TTAG5 engine with a 600KW/750KVA generator set configuration for dependable prime and standby power.

○ Perkins 2806A-E18TTAG5 diesel engine for reliable high-power generation

○ 600KW/750KVA prime power and 660KW/825KVA standby power

○ 600KW/750KVA alternator configuration

○ Multiple voltage configurations available

○ Open and silent type configurations available

○ Electronic engine control for precise engine speed and performance management

○ Suitable for commercial, industrial and backup power applications

○ Factory-direct supply with customized generator set solutions

For more information, please visit the GENLITEC POWER® Why Choose GENLITEC POWER page.

Warranty

GENLITEC POWER provides a standard warranty of 12 months or 1000 working hours, whichever comes first. For details, please refer to the GENLITEC POWER® Warranty Policy.

FAQ

Q: What is the rated power of the GPP750D5-I / GPP750S5-I generator set?
A: The generator set provides 600KW/750KVA prime power and 660KW/825KVA standby power at 50Hz and 1500 RPM.
Q: Which diesel engine is used in the GPP750D5-I / GPP750S5-I?
A: The generator set is powered by a Perkins 2806A-E18TTAG5 six-cylinder, 18.1L turbocharged and air-to-air charge cooled diesel engine with electronic engine control.
Q: What voltage configurations are available?
A: The available rated voltage configurations are 220/380V, 230/400V and 240/415V.
Q: What is the difference between the open and silent type generator sets?
A: The GPP750D5-I is the open type model, while the GPP750S5-I is equipped with a sound-attenuated enclosure for applications where lower noise levels and weather protection are required.
Q: What is the fuel consumption of the GPP750D5-I / GPP750S5-I?
A: Based on Perkins 2806A-E18TTAG5 fuel consumption data at 1500 RPM, fuel consumption is approximately 180 L/H at standby power, 162 L/H at 100% prime load, 118 L/H at 75% prime load and 80 L/H at 50% prime load.
Q: What is the fuel tank capacity?
A: The standard fuel tank capacity is 1000L. Larger fuel tanks are available as optional configurations for extended operating time.
Q: What is the frequency and rated speed of the generator set?
A: The generator set operates at 50Hz with a rated engine speed of 1500 RPM.
Q: How many cylinders does the Perkins 2806A-E18TTAG5 engine have?
A: The Perkins 2806A-E18TTAG5 is a six-cylinder vertical in-line diesel engine with an 18.1L displacement.
Q: What are the bore and stroke of the Perkins 2806A-E18TTAG5 engine?
A: The engine has a bore of 145 mm and a stroke of 183 mm, with a compression ratio of 14:1.
Q: What is the warranty period for the GPP750D5-I / GPP750S5-I?
A: GENLITEC POWER provides a standard warranty of 12 months or 1000 working hours, whichever comes first.

  • Previous: 60Hz 450kW 563kVA Diesel Generator with Perkins 2506C-E15TAG3 Engine
  • Next: 60Hz 300kW 375kVA Diesel Generator with Cummins 6ZTAA13-G3 Engine

  • Related Products