?> 60Hz 600kW 750kVA Perkins 4006-23TAG2A Diesel Generator

60Hz 600kW 750kVA Diesel Generator with Perkins 4006-23TAG2A Engine

60Hz 600kW 750kVA Diesel Generator with Perkins 4006-23TAG2A Engine - Image 1
  • 60Hz 600kW 750kVA Diesel Generator with Perkins 4006-23TAG2A Engine - Image 1
  • 60Hz 600kW 750kVA Diesel Generator with Perkins 4006-23TAG2A Engine - Image 2

Short Description

GENLITEC POWER GPP750D6 / GPP750S6 diesel generator set powered by Perkins 4006-23TAG2A, with prime power 600kW/750kVA, standby power 660kW/825kVA.

  • ModelGPP750S6
  • Prime Power (PRP)600kW/750kVA
  • Standby Power (ESP)660kW/825kVA
  • Engine4006-23TAG2A
  • Fuel Consumption (100%)176L/H
Share

Product Details

Product Tags

60Hz 750kVA Diesel Generator with Perkins 4006-23TAG2A Diesel Engine

Introduction

The GENLITEC POWER GPP750D6 / GPP750S6 diesel generator set is a powerful and reliable power solution designed for prime, standby and backup power applications.

Powered by a Perkins 4006-23TAG2A 6-cylinder turbocharged and air-to-air charge cooled diesel engine, the generator set delivers 600kW/750kVA prime power and 660kW/825kVA standby power at 60Hz and 1800RPM, with multiple voltage configurations available for different applications.

Generator Set

Open Type Model GPP750D6
Silent Type Model GPP750S6
Frequency 60Hz
Phase & Wires 3 Phase, 4 Wires
Power Factor 0.8
Prime Power 600kW/750kVA
Standby Power 660kW/825kVA
Rated Voltage 120/208V; 127/220V; 220/380V; 254/440V
Rated Speed 1800 RPM
Fuel Tank Capacity 1000L

Diesel Engine

Engine Model Perkins 4006-23TAG2A
Cylinder Number 6
Cylinder Arrangement Vertical In-line
Engine Type 4-Cycle Diesel
Aspiration System Turbocharged, Air-to-Air Charge Cooled
Cooling Method Water Cooled
Governor Type Electronic
Bore x Stroke 160 x 190 mm
Compression Ratio 13.6:1
Rated Speed 1800 RPM
Displacement 22.921L
Rated Power 684kW @ 1800RPM
Standby Power 759kW @ 1800RPM
Fuel System Direct injection
Oil Capacity 113.4L
Coolant Capacity 105L
Electric Starting System DC 24V
Battery Charging Alternator 70A

Fuel Consumption

100% Prime Load 176L/H
75% Prime Load 126L/H
50% Prime Load 88L/H
25% Prime Load -
100% Standby Load 196L/H

Alternator

Number of Phase 3
Rated Power 620kW/775kVA
Frequency 60Hz
Power Factor 0.8
Poles 4
Temperature Rise 125K
Terminals 6 (12-lead for option)
Insulation Class H Class
Ambient Temperature 40℃
IP Rating IP23
Excitation System Self-Excited
Bearing Single Bearing
Coating Vacuum Impregnation
Voltage Regulator A.V.R
Coupling Flexible Disc

Control Panel

○ Emergency stop button ○ Main circuit breaker
○ Float battery charger ○ Manual/Auto start control panel
○ Fuel level meter ○ Controller power switch
○ Alarm buzzer

SOUND ATTENUATED ENCLOSURE

The GPP750S6 silent type generator set is equipped with a sound-attenuated enclosure designed to reduce operating noise and provide reliable protection for outdoor applications.

○ Sound-attenuated enclosure for reduced noise levels

○ Weatherproof design for outdoor installation

○ Internal exhaust silencer for effective noise reduction

○ Corrosion-resistant construction for long-term outdoor use

○ Service access doors for convenient maintenance

○ Suitable for commercial, industrial and standby power applications

Options

○ ATS for automatic start and stop when utility power fails or returns

○ Remote Monitoring System

○ Water-Jacket Heater

○ Synchronization System

○ AREP Excitation System

○ PMG Excitation System

Applications

The GENLITEC POWER 600kW/750kVA diesel generator set is suitable for a wide range of prime, standby and backup power applications, including:

○ Commercial and office buildings

○ Industrial facilities

○ Construction and job sites

○ Agricultural and rural facilities

○ Telecommunication and remote sites

○ Emergency and standby power systems

Why Choose GENLITEC POWER

GENLITEC POWER diesel generator sets are designed to provide dependable power, practical configuration and reliable performance for a wide range of applications.

○ Perkins 4006-23TAG2A turbocharged and air-to-air charge cooled diesel engine for reliable and efficient power generation

○ Prime and standby power configurations for different operating requirements

○ Multiple voltage configurations available

○ Open and silent type configurations available

○ Suitable for commercial, industrial and backup power applications

○ Factory-direct supply with customized generator set solutions

For more information, please visit the GENLITEC POWER® Why Choose GENLITEC POWER page.

Warranty

GENLITEC POWER provides a standard warranty of 12 months or 1000 working hours, whichever comes first. For details, please refer to the GENLITEC POWER® Warranty Policy.

FAQ

Q: What is the rated power of the GPP750D6 / GPP750S6 generator set?
A: The generator set provides 600kW/750kVA prime power and 660kW/825kVA standby power.
Q: Which diesel engine is used in the GPP750D6 / GPP750S6?
A: The generator set is powered by a Perkins 4006-23TAG2A 6-cylinder, 22.921L turbocharged and air-to-air charge cooled diesel engine with electronic governing.
Q: What voltage configurations are available?
A: The available rated voltage configurations are 120/208V, 127/220V, 220/380V and 254/440V.
Q: What is the difference between the open and silent type generator sets?
A: The GPP750D6 is the open type model, while the GPP750S6 is equipped with a sound-attenuated enclosure for applications where lower noise levels and weather protection are required.
Q: What is the frequency and rated speed of the generator set?
A: The generator set operates at 60Hz with a rated speed of 1800 RPM.
Q: Can remote monitoring and a water-jacket heater be supplied?
A: Yes. Remote Monitoring System and Water-Jacket Heater are available as optional equipment.
Q: What is the warranty period for the GPP750D6 / GPP750S6?
A: GENLITEC POWER provides a standard warranty of 12 months or 1000 working hours, whichever comes first.

  • Previous: 50Hz 300kW 375kVA Diesel Generator with Deutz TCD12.1 G2 Engine
  • Next: 50Hz 720kW 900kVA Diesel Generator with Perkins 4008TAG1A Engine

  • Related Products