?> 60Hz Standby 600kW 750kVA Cummins KTAA19-G6A Diesel Genset

60Hz Standby 600kW 750kVA Diesel Generator with Cummins KTAA19-G6A Engine

60Hz Standby 600kW 750kVA Diesel Generator with Cummins KTAA19-G6A Engine - Image 1
  • 60Hz Standby 600kW 750kVA Diesel Generator with Cummins KTAA19-G6A Engine - Image 1
  • 60Hz Standby 600kW 750kVA Diesel Generator with Cummins KTAA19-G6A Engine - Image 2
  • 60Hz Standby 600kW 750kVA Diesel Generator with Cummins KTAA19-G6A Engine - Image 3
  • 60Hz Standby 600kW 750kVA Diesel Generator with Cummins KTAA19-G6A Engine - Image 4

Short Description

GENLITEC POWER GPC750D6-SP / GPC750S6-SP 750kVA standby diesel generator with Cummins KTAA19-G6A engine, delivering reliable 600kW/750kVA standby power.

  • ModelGPC750S6-SP
  • Prime Power (PRP)N/A
  • Standby Power (ESP)600kW/750kVA
  • EngineKTAA19-G6A
  • Fuel Consumption (100%)140L/H
Share

Product Details

Product Tags

750kVA Cummins diesel generator set GPC750D6-SP open type and GPC750S6-SP silent type

Introduction

The GENLITEC POWER® GPC750D6-SP open type and GPC750S6-SP silent type diesel generator sets are designed for standby power applications, delivering 600kW/750kVA standby power. Powered by a reliable CUMMINS KTAA19-G6A six-cylinder, turbocharged and air-air intercooled diesel engine and matched with a brushless copper alternator, these generator sets provide stable and dependable backup power for commercial, industrial, construction and emergency applications.

Designed for 60Hz operation at 1800RPM, the generator sets provide three-phase, four-wire output with voltage options including 120/208V, 127/220V, 220/380V and 254/440V. The GPC750S6-SP silent type features a weatherproof sound-attenuated enclosure with internal exhaust silencer, while the GPC750D6-SP open type provides convenient access for installation, inspection and maintenance. Optional ATS, synchronization system, remote monitoring, heaters and PMG & AREP are available according to application requirements.

Generator Set

Open Type Model GPC750D6-SP
Silent Type Model GPC750S6-SP
Prime Power N/A
Standby Power 600kW/750kVA
Phase & Wire 3 Phase, 4 Wires
Power Factor 0.8
Frequency 60Hz
Rated Voltage 120/208V, 127/220V, 220/380V, 254/440V
Rated Speed 1800RPM
Fuel Tank Capacity 1000L

Diesel Engine

Engine Model CUMMINS KTAA19-G6A
Cylinder Number 6
Cylinder Arrangement 6 Cylinders in Line
Engine Type 4-Stroke, Water-Cooled Diesel
Aspiration System Turbocharged and Air-Air Intercooled
Cooling Method Water Cooled
Governor Type Electronic
Fuel System Cummins PT Fuel System
Bore x Stroke 159 x 159 mm
Compression Ratio 13.9:1
Rated Speed 1800RPM
Displacement 18.9L
Prime Power N/A
Standby Power 664kW / 890BHP @ 1800RPM
Oil Capacity 50L
Coolant Capacity 30L
Electric Starting System DC 24V

Fuel Consumption

100% Standby Load 161.2L/H
75% Standby Load 140.0L/H
50% Standby Load 106.5L/H
25% Standby Load 73.3L/H

Alternator

Number of Phase 3
Rated Power 570kW/712.5kVA
Frequency 60Hz
Power Factor 0.8
Poles 4
Temperature Rise 125K
Terminals 12
Insulation Class H
Ambient Temperature 40°C
IP Rating IP23
Excitation System Self-Excited
Bearing Single Bearing
Coating Vacuum Impregnation
Voltage Regulator AVR
Coupling Flexible Disc

Control Panel

○ Emergency stop button ○ Main circuit breaker
○ Float battery charger ○ Manual/Auto start control panel
○ Fuel level meter ○ Controller power switch
○ Alarm buzzer

Sound Attenuated Enclosure

○ Fully weatherproof sound-attenuated enclosure with internal exhaust silencer

○ Highly corrosion-resistant construction

○ Available for GPC750S6-SP silent type generator set

Options

○ ATS panel for automatic start and stop when utility power fails or returns

○ Synchronization system

○ Remote Monitoring System

○ Water-jacket heater

○ Space heater

○ PMG & AREP

Applications

The GENLITEC POWER 600kW/750kVA standby diesel generator set is suitable for a wide range of emergency and backup power applications, including:

○ Commercial buildings

○ Industrial facilities

○ Construction sites

○ Agricultural facilities

○ Telecommunication facilities

○ Emergency and backup power applications

Why Choose GENLITEC POWER

GENLITEC POWER provides diesel generator sets and mobile lighting towers for construction, mining, telecommunications, infrastructure, industrial, commercial and other demanding applications. We offer flexible configurations, international engine and alternator brands, customized power solutions, technical support and after-sales service.

○ Diesel generator sets and mobile lighting towers from one supplier

○ Multiple engine, alternator and controller brand options

○ Customized power solutions for different applications

○ Professional manufacturing and quality control

○ International export and project experience

○ Technical support and after-sales service

For more information, please visit the GENLITEC POWER® Why Choose GENLITEC POWER page.

Warranty

GENLITEC POWER provides a standard warranty of 12 months or 1000 working hours, whichever comes first. For details, please refer to the GENLITEC POWER® Warranty Policy.

Frequently Asked Questions

Q: What is the rated power of the GPC750D6-SP and GPC750S6-SP diesel generator sets?
A: The generator sets are designed for standby power only, providing 600kW/750kVA standby power. Prime power is not available for this model.
Q: What diesel engine is used in this generator set?
A: The generator set is powered by a CUMMINS KTAA19-G6A six-cylinder, 18.9L turbocharged and air-air intercooled diesel engine with an electronic governor, operating at 1800RPM for 60Hz standby applications.
Q: What voltage configurations are available?
A: Available voltage configurations include 120/208V, 127/220V, 220/380V and 254/440V, subject to the selected generator configuration.
Q: Is a silent type version available?
A: Yes. The GPC750S6-SP is the silent type version equipped with a weatherproof sound-attenuated enclosure and internal exhaust silencer.
Q: Can the generator set be supplied with an ATS?
A: Yes. An ATS can be supplied as an option for automatic generator start and stop when the utility power fails or returns.
Q: What warranty is provided?
A: The standard warranty is 12 months or 1000 working hours, whichever comes first.

  • Previous: 50Hz 1800kW 2250kVA Diesel Generator with Perkins 4016-61TRG3 Engine
  • Next: 60Hz 1360kW 1700kVA Diesel Generator with Perkins 4012-46TAG3A Engine

  • Related Products