?> 50Hz 800kW 1000kVA Perkins 4008TAG2A Diesel Generator

50Hz 800kW 1000kVA Diesel Generator with Perkins 4008TAG2A Engine

50Hz 800kW 1000kVA Diesel Generator with Perkins 4008TAG2A Engine - Image 1
  • 50Hz 800kW 1000kVA Diesel Generator with Perkins 4008TAG2A Engine - Image 1
  • 50Hz 800kW 1000kVA Diesel Generator with Perkins 4008TAG2A Engine - Image 2

Short Description

GENLITEC POWER GP1000D5/GPP1000S5 diesel generator set powered by original Perkins 4008TAG2A, with prime power 800KW/1000KVA, standby power 880KW/1100KVA.

  • ModelGPP1000S5
  • Prime Power (PRP)800kW/1000kVA
  • Standby Power (ESP)880kW/1100kVA
  • Engine4008TAG2A
  • Fuel consumption (100%)215L/H
Share

Product Details

Product Tags

50Hz 800KW 1000KVA Diesel Generator with Perkins 4008TAG2A Diesel Engine

Introduction

The GENLITEC POWER GPP1000D5 / GPP1000S5 is a 1000 kVA diesel generator set designed for reliable prime, standby and backup power applications. With a rated output of 800KW/1000KVA prime power and 880KW/1100KVA standby power, this 50Hz diesel generator operates at 1500 RPM and provides dependable three-phase power for commercial, industrial, construction, agricultural, telecommunications and other demanding applications.

Powered by a Perkins 4008TAG2A turbocharged and air-to-air charge cooled diesel engine, the GPP1000D5 / GPP1000S5 combines a 30.56L eight-cylinder engine with electronic engine governing, high power density and efficient fuel consumption. The generator set is available in both open type and silent type versions, with rated voltage options of 220/380V, 230/400V and 240/415V. A 1000L standard fuel tank is provided, while optional ATS panel, synchronization system, remote monitoring system and other accessories are available for different project requirements. This 800KW/1000KVA Perkins diesel generator is suitable for prime power, emergency standby power and backup power applications where reliable and efficient electricity supply is required.

Generator Set

Open Type Model GPP1000D5
Silent Type Model GPP1000S5
Frequency 50Hz
Phase & Wires 3 Phase, 4 Wires
Power Factor 0.8
Prime Power 800KW/1000KVA
Standby Power 880KW/1100KVA
Rated Voltage 220/380V; 230/400V; 240/415V
Rated Speed 1500 RPM
Fuel Tank Capacity 1000L

Diesel Engine

Engine Model Perkins 4008TAG2A
Cylinder Number 8
Cylinder Arrangement Vertical In-line
Cycle 4 Stroke
Aspiration System Turbocharged and Air-to-Air Charge Cooled
Cooling Method Liquid Cooled
Governor Type Electronic
Bore x Stroke 160 x 190 mm
Compression Ratio 13.6:1
Rated Speed 1500 RPM
Displacement 30.56L
Engine Power - Prime 899KW Gross / 861KW Net
Engine Power - Standby 985KW Gross / 947KW Net
Combustion System Direct Injection
Coolant Capacity Approximately 162L
Oil Capacity Approximately 153L
Electric Starting System DC 24V

Fuel Consumption

Standby Power Rating 240L/H
100% Prime Load 215L/H
Baseload Power Rating N/A
75% Prime Load 162L/H
50% Prime Load 111L/H

Alternator

Number of Phase 3
Rated Power 800KW/1000KVA
Frequency 50Hz
Power Factor 0.8
Poles 4
Temperature Rise 125K
Terminals 6/12
Insulation Class H
Ambient Temperature 40℃
IP Rating IP23
Excitation System Self-Excited
Bearing Single Bearing
Coating Vacuum Impregnation
Voltage Regulator A.V.R
Coupling Flexible Disc

Control Panel

○ Emergency stop button ○ Main circuit breaker
○ Float battery charger ○ Manual/Auto start control panel
○ Fuel level meter ○ Controller power switch
○ Alarm buzzer

Sound Attenuated Enclosure

○ Weatherproof sound-attenuated enclosure with internal exhaust silencer

○ Corrosion-resistant construction for outdoor installation

○ Available for GPP1000S5 silent type generator set

Options

○ ATS for automatic start and stop when utility power fails or returns

○ Synchronization System

○ Remote monitoring system

○ Water-Jacket Heater

○ Other Heaters

○ 20GP ISO containerized canopy with CSC certification for international transportation

Applications

The GENLITEC POWER 800KW/1000KVA diesel generator set is suitable for a wide range of prime, standby and backup power applications, including:

○ Commercial and office buildings

○ Industrial facilities

○ Construction and job sites

○ Agricultural and rural facilities

○ Telecommunication and remote sites

○ Emergency and standby power systems

Why Choose GENLITEC POWER

GENLITEC POWER GPP1000D5 / GPP1000S5 diesel generator sets combine a Perkins 4008TAG2A engine with a high-power generator set configuration for dependable prime and standby power.

○ Perkins 4008TAG2A diesel engine for reliable high-power generation

○ 800KW/1000KVA prime power and 880KW/1100KVA standby power

○ 30.56L eight-cylinder engine with turbocharged and air-to-air charge cooled induction

○ 800KW/1000KVA alternator for high-power generator applications

○ Multiple voltage configurations available

○ Open and silent type configurations available

○ Electronic engine governing for precise engine speed and performance management

○ Suitable for commercial, industrial and backup power applications

○ Factory-direct supply with customized generator set solutions

For more information, please visit the GENLITEC POWER® Why Choose GENLITEC POWER page.

Warranty

GENLITEC POWER provides a standard warranty of 12 months or 1000 working hours, whichever comes first. For details, please refer to the GENLITEC POWER® Warranty Policy.

FAQ

Q: What is the rated power of the GPP1000D5 / GPP1000S5 generator set?
A: The generator set provides 800KW/1000KVA prime power and 880KW/1100KVA standby power at 50Hz and 1500 RPM.
Q: Which diesel engine is used in the GPP1000D5 / GPP1000S5?
A: The generator set is powered by a Perkins 4008TAG2A eight-cylinder, 30.56L turbocharged and air-to-air charge cooled diesel engine with electronic governing.
Q: What voltage configurations are available?
A: The available rated voltage configurations are 220/380V, 230/400V and 240/415V.
Q: What is the difference between the open and silent type generator sets?
A: The GPP1000D5 is the open type model, while the GPP1000S5 is equipped with a sound-attenuated enclosure for applications where lower noise levels and weather protection are required.
Q: What is the fuel consumption of the GPP1000D5 / GPP1000S5?
A: Based on Perkins 4008TAG2A fuel consumption data at 1500 RPM, the fuel consumption is approximately 249 L/H at standby power, 224 L/H at 100% prime load, 173 L/H at continuous baseload, 162 L/H at 75% prime load and 108 L/H at 50% prime load.
Q: What is the fuel tank capacity?
A: The standard fuel tank capacity is 1000L. Larger fuel tanks are available as optional configurations for extended operating time.
Q: What is the frequency and rated speed of the generator set?
A: The generator set operates at 50Hz with a rated engine speed of 1500 RPM.
Q: How many cylinders does the Perkins 4008TAG2A engine have?
A: The Perkins 4008TAG2A is an eight-cylinder vertical in-line diesel engine with a 30.56L displacement.
Q: What are the bore and stroke of the Perkins 4008TAG2A engine?
A: The engine has a bore of 160 mm and a stroke of 190 mm, with a compression ratio of 13.6:1.
Q: What is the engine oil and coolant capacity?
A: The Perkins 4008TAG2A has an oil capacity of approximately 153L and a coolant capacity of approximately 162L.
Q: What is the warranty period for the GPP1000D5 / GPP1000S5?
A: GENLITEC POWER provides a standard warranty of 12 months or 1000 working hours, whichever comes first.