50Hz 320kW 400kVA Diesel Generator with Cummins 6ZTAA13-G2 Engine

50Hz 320kW 400kVA Diesel Generator with Cummins 6ZTAA13-G2 Engine - Image 1
  • 50Hz 320kW 400kVA Diesel Generator with Cummins 6ZTAA13-G2 Engine - Image 1
  • 50Hz 320kW 400kVA Diesel Generator with Cummins 6ZTAA13-G2 Engine - Image 2
  • 50Hz 320kW 400kVA Diesel Generator with Cummins 6ZTAA13-G2 Engine - Image 3
  • 50Hz 320kW 400kVA Diesel Generator with Cummins 6ZTAA13-G2 Engine - Image 4

Short Description

GENLITEC POWER® GPC400D5/GPC400S5 diesel generator set with original CUMMINS 6ZTAA13-G2, 320KW/400KVA prime and 352KW/440KVA standby power.

  • ModelGPC400D5 | GPC400S5
  • Frequencyf50Hz
  • Prime Power320KW/400KVA
  • Standby Power352KW/440KVA
  • EngineCummins 6ZTAA13-G2
  • AlternatorStamford/Leroy Somer/Genlitec Power
  • Fuel Consumption (100% Load)89.1L/H
  • MOQ1 Set

Product Details

Product Tags

Video

400kVA Cummins diesel generator set GPC400D5 open type and GPC400S5 silent type

Introduction

The GENLITEC POWER® GPC400D5 open type and GPC400S5 silent type diesel generator sets deliver 320kW/400kVA prime power and 352kW/440kVA standby power. Powered by a Cummins 6ZTAA13-G2 six-cylinder diesel engine and matched with a brushless copper alternator, this 400kVA generator set is designed for demanding industrial, commercial, construction, mining, infrastructure and standby power applications.

The Cummins 6ZTAA13-G2 engine features a 13L displacement, turbocharged air-to-air charge air cooling, electronic governor and 1500 RPM operating speed, providing strong power output and stable engine speed under changing loads. The 24V DC electric starting system and water-cooled design support dependable operation in demanding working environments.

With a 600L fuel tank, flexible voltage configurations of 220/380V, 230/400V and 240/415V, and a 320kW/400kVA alternator rated for 40℃ ambient temperature, the GPC400 series provides a practical balance of power, durability and operating flexibility. The GPC400D5 open type is suitable for generator rooms and applications requiring convenient service access, while the GPC400S5 silent type uses a weatherproof sound-attenuated enclosure for outdoor and noise-sensitive installations.

Generator Set

Open Type Model GPC400D5
Silent Type Model GPC400S5
Prime Power 320KW/400KVA
Standby Power 352KW/440KVA
Phase & Wire 3 Phase, 4 Wires
Power Factor 0.8
Frequency 50Hz
Voltage 220/380V, 230/400V, 240/415V
Fuel Tank Capacity 600L

Diesel Engine

Engine Model CUMMINS 6ZTAA13-G2
Cylinder Number 6
Aspiration System Turbocharged, Air to Air Cooled
Cooling Method Water Cooled
Governor Type Electronic
Bore x Stroke 130 x 163 mm
Compression Ratio 17:1
Rated Speed 1500 RPM
Displacement 13L
Rated Power 390KW
Standby Power 415KW
Fuel Pump BYC PD Pump
Oil Capacity 45.42L
Coolant Capacity 23.1L (Engine Only)
Electric Starting System DC 24V

Fuel Consumption

100% Prime Load 89.1L/H
75% Prime Load 65.1L/H
50% Prime Load 43.2L/H
25% Prime Load 23.6L/H

Alternator

Number of Phase 3
Rated Power 320KW/400KVA
Frequency 50Hz
Power Factor 0.8
Poles 4
Temperature Rise 125K
Terminals 12
Insulation Class H Class
Ambient Temperature 40℃
IP Rating IP23
Excitation System Self-Excited
Bearing Single Bearing
Coating Vacuum Impregnation
Voltage Regulator A.V.R
Coupling Flexible Disc

Control Panel

○ Emergency stop button ○ Main circuit breaker
○ Float battery charger ○ Manual/Auto start control panel
○ Fuel level meter ○ Controller power switch
○ Alarm buzzer

Sound Attenuated Enclosure

○ Weatherproof sound-attenuated enclosure with internal exhaust silencer

○ Corrosion-resistant construction for outdoor installation

○ Available for GPC400S5 silent type generator set

Options

○ ATS for automatic start and stop when utility power fails or returns

○ 12-hour fuel tank

○ 24-hour fuel tank

○ Water-jacket heater

○ Other heaters

○ AREM & PMG

○ Synchronization System

○ Remote & Monitoring System

Applications

The GENLITEC POWER 320kW/400kVA diesel generator set is suitable for demanding prime, standby and backup power applications, including:

○ Commercial buildings and office complexes

○ Industrial facilities and manufacturing plants

○ Construction sites and infrastructure projects

○ Mining and heavy-duty applications

○ Telecommunication and remote facilities

○ Data centers and critical power systems

○ Emergency and standby power applications

Why Choose GENLITEC POWER

GENLITEC POWER combines established engine technology, carefully selected generator components and professional assembly to deliver dependable power generation equipment for demanding applications. The GPC400 series is configured around the Cummins 6ZTAA13-G2 engine, a high-output 13L six-cylinder diesel engine designed for reliable continuous operation and strong load response.

○ Genuine Cummins 6ZTAA13-G2 diesel engine configuration

○ 320kW/400kVA prime power for demanding applications

○ 13L six-cylinder engine with turbocharged air-to-air charge air cooling

○ Electronic governor for stable speed and reliable frequency control

○ 600L standard fuel tank for extended operating periods

○ High-quality alternator with H Class insulation and IP23 protection

○ Open and silent type configurations for different installation environments

○ ATS, synchronization and remote monitoring options available

○ Professional manufacturing, testing and international export experience

For more information, please visit the GENLITEC POWER® Why Choose GENLITEC POWER page.

Warranty

GENLITEC POWER provides a standard warranty of 12 months or 1000 working hours, whichever comes first. For details, please refer to the GENLITEC POWER® Warranty Policy.

Frequently Asked Questions

Q: What is the power rating of the GPC400D5 and GPC400S5 generator sets?
A: The GPC400D5 open type and GPC400S5 silent type provide 320kW/400kVA prime power and 352kW/440kVA standby power at 50Hz.
Q: Which Cummins engine is used in the 400kVA generator set?
A: The GPC400 series is powered by the Cummins 6ZTAA13-G2, a six-cylinder 13L diesel engine with turbocharged air-to-air charge air cooling, electronic governor and 1500 RPM rated speed.
Q: What fuel tank capacity is provided with the GPC400 generator set?
A: The standard GPC400D5 and GPC400S5 configurations are equipped with a 600L fuel tank, with larger-capacity fuel tanks available as options for extended operating requirements.
Q: What voltage configurations are available?
A: The generator set can be configured for 220/380V, 230/400V or 240/415V, depending on project requirements and the selected alternator configuration.
Q: What is the difference between the GPC400D5 and GPC400S5?
A: The GPC400D5 is the open type configuration for generator rooms and installations where ventilation and service access are important. The GPC400S5 is equipped with a sound-attenuated weatherproof enclosure for outdoor and noise-sensitive applications.
Q: Can the GPC400 generator set be used for continuous prime power?
A: Yes. The GPC400 series provides 320kW/400kVA prime power and is designed for demanding applications requiring reliable long-duration power generation, subject to the applicable operating conditions and load profile.
Q: Are ATS and synchronization systems available?
A: Yes. ATS, synchronization, remote monitoring, water-jacket heater and other configuration options are available according to the project requirements.
Q: What warranty is provided for the GPC400 series?
A: The standard warranty is 12 months or 1000 working hours, whichever comes first.

  • Previous: 750KVA Perkins Diesel Generator-60Hz