GENLITEC GPP250D5-II/GPP250S5-II 250kVA/200kW 50Hz diesel generators with Perkins 1506A-E88TAG3 engine for reliable prime and standby power.

  • ModelGPP250D5-II | GPP250S5-II
  • Frequency50Hz
  • Prime Power200kW/250kVA
  • Standby Power220kW/275kVA
  • EnginePerkins 1506A-E88TAG3
  • Fuel Consumption (100% Load)55.5L/H
  • MOQ1 Set

Product Details

Product Tags

50Hz 200KW 250KVA Diesel Generator with Perkins 1506A-E88TAG3 Diesel Engine

Introduction

The GENLITEC POWER GPP250D5-II / GPP250S5-II is a 250 kVA diesel generator set designed for reliable prime, standby and backup power applications. With a rated output of 200KW/250KVA prime power and 220KW/275KVA standby power, this 50Hz diesel generator operates at 1500 RPM and provides dependable three-phase power for commercial, industrial, construction, agricultural, telecommunications and other demanding applications.

Powered by a Perkins 1506A-E88TAG3 turbocharged aftercooled diesel engine, the GPP250D5-II / GPP250S5-II combines an 8.8L six-cylinder engine with electronic governing, practical power output and efficient fuel consumption. The generator set is available in both open type and silent type versions, with rated voltage options of 220/380V, 230/400V and 240/415V. A 380L standard fuel tank is provided, while optional 12-hour, 24-hour fuel tanks, ATS, trailer, remote monitoring system and synchronization system are available for different project requirements. This 200KW/250KVA Perkins diesel generator is suitable for prime power, emergency standby power and backup power applications where reliable and economical electricity supply is required.

Generator Set

Open Type Model GPP250D5-II
Silent Type Model GPP250S5-II
Frequency 50Hz
Phase & Wires 3 Phase, 4 Wires
Power Factor 0.8
Prime Power 200KW/250KVA
Standby Power 220KW/275KVA
Rated Voltage 220/380V; 230/400V; 240/415V
Rated Speed 1500 RPM
Fuel Tank Capacity 380L

Diesel Engine

Engine Model Perkins 1506A-E88TAG3
Cylinder Number 6
Cylinder Arrangement Vertical In-line
Cycle 4 Stroke
Aspiration System Turbocharged Aftercooled
Cooling Method Water Cooled
Governor Type Electronic ECM
Bore x Stroke 112 x 149 mm
Compression Ratio 16.1:1
Rated Speed 1500 RPM
Displacement 8.8L
Rated Power 222KW
Standby Power 244KW
Combustion System Direct Injection
Oil Capacity 41L
Coolant Capacity 29.6L
Electric Starting System DC 24V

Fuel Consumption

100% Prime Load 55.5L/H
75% Prime Load 41.6L/H
50% Prime Load 28.9L/H
25% Prime Load 15.4L/H

Alternator

Number of Phase 3
Rated Power 200KW/250KVA
Frequency 50Hz
Power Factor 0.8
Poles 4
Temperature Rise 125K
Terminals 12
Insulation Class H Class
Ambient Temperature 40℃
IP Rating IP23
Excitation System Self-Excited
Bearing Single Bearing
Coating Vacuum Impregnation
Voltage Regulator A.V.R
Coupling Flexible Disc

Control Panel

○ Emergency stop button ○ Main circuit breaker
○ Float battery charger ○ Manual/Auto start control panel
○ Fuel level meter ○ Controller power switch
○ Alarm buzzer

Sound Attenuated Enclosure

○ Weatherproof sound-attenuated enclosure with internal exhaust silencer

○ Corrosion-resistant construction for outdoor installation

○ Available for GPP250S5-II silent type generator set

Options

○ ATS for automatic start and stop when utility power fails or returns

○ Double-axle trailer

○ 12-hour fuel tank

○ 24-hour fuel tank

○ Remote monitoring system

○ Synchronization system

Applications

The GENLITEC POWER 200KW/250KVA diesel generator set is suitable for a wide range of prime, standby and backup power applications, including:

○ Commercial and office buildings

○ Industrial facilities

○ Construction and job sites

○ Agricultural and rural facilities

○ Telecommunication and remote sites

○ Emergency and standby power systems

Why Choose GENLITEC POWER

GENLITEC POWER GPP250D5-II / GPP250S5-II diesel generator sets combine a Perkins 1506A-E88TAG3 engine with a practical generator set configuration for dependable prime and standby power.

○ Perkins 1506A-E88TAG3 diesel engine for reliable power generation

○ 200KW/250KVA prime power and 220KW/275KVA standby power

○ Multiple voltage configurations available

○ Open and silent type configurations available

○ Electronic governor for precise engine speed control

○ Suitable for commercial, industrial and backup power applications

○ Factory-direct supply with customized generator set solutions

For more information, please visit the GENLITEC POWER® Why Choose GENLITEC POWER page.

Warranty

GENLITEC POWER provides a standard warranty of 12 months or 1000 working hours, whichever comes first. For details, please refer to the GENLITEC POWER® Warranty Policy.

FAQ

Q: What is the rated power of the GPP250D5-II / GPP250S5-II generator set?
A: The generator set provides 200KW/250KVA prime power and 220KW/275KVA standby power.
Q: Which diesel engine is used in the GPP250D5-II / GPP250S5-II?
A: The generator set is powered by a Perkins 1506A-E88TAG3 turbocharged aftercooled diesel engine with electronic ECM governing.
Q: What voltage configurations are available?
A: The available rated voltage configurations are 220/380V, 230/400V and 240/415V.
Q: What is the difference between the open and silent type generator sets?
A: The GPP250D5-II is the open type model, while the GPP250S5-II is equipped with a sound-attenuated enclosure for applications where lower noise levels and weather protection are required.
Q: What is the fuel consumption of the GPP250D5-II / GPP250S5-II?
A: The Perkins 1506A-E88TAG3 engine has a fuel consumption of approximately 55.5 L/H at 100% prime load, 41.6 L/H at 75% prime load and 28.9 L/H at 50% prime load.
Q: What is the fuel tank capacity?
A: The standard fuel tank capacity is 380L. Larger fuel tanks are available as optional configurations for extended operating time.
Q: What is the frequency and rated speed of the generator set?
A: The generator set operates at 50Hz with a rated engine speed of 1500 RPM.
Q: How many cylinders does the Perkins 1506A-E88TAG3 engine have?
A: The Perkins 1506A-E88TAG3 is a six-cylinder diesel engine with an 8.8L displacement.
Q: What are the bore and stroke of the Perkins 1506A-E88TAG3 engine?
A: The engine has a bore of 112 mm and a stroke of 149 mm, with a compression ratio of 16.1:1.
Q: What is the warranty period for the GPP250D5-II / GPP250S5-II?
A: GENLITEC POWER provides a standard warranty of 12 months or 1000 working hours, whichever comes first.