?> 60Hz 720kW 900kVA Perkins 4006-23TAG4 Diesel Generator

60Hz 720kW 900kVA Diesel Generator with Perkins 4006-23TAG4 Engine

60Hz 720kW 900kVA Diesel Generator with Perkins 4006-23TAG4 Engine - Image 1
  • 60Hz 720kW 900kVA Diesel Generator with Perkins 4006-23TAG4 Engine - Image 1
  • 60Hz 720kW 900kVA Diesel Generator with Perkins 4006-23TAG4 Engine - Image 2

Short Description

GENLITEC POWER GPP900D6 / GPP900S6 diesel generator set powered by Perkins 4006-23TAG4, with prime power 720kW/900kVA, standby power 800kW/1000kVA.

  • ModelGPP900S6
  • Prime Power (PRP)720kW/900kVA
  • Standby Power (ESP)800kW/1000kVA
  • Engine4006-23TAG4
  • Fuel Consumption (100%)200L/H
Share

Product Details

Product Tags

60Hz 900kVA Diesel Generator with Perkins 4006-23TAG4 Diesel Engine

Introduction

The GENLITEC POWER GPP900D6 / GPP900S6 diesel generator set is a powerful and reliable power solution designed for prime, standby and backup power applications.

Powered by a Perkins 4006-23TAG4 6-cylinder, 23L turbocharged and air-to-air charge cooled diesel engine, the generator set delivers 720kW/900kVA prime power and 800kW/1000kVA standby power at 60Hz and 1800RPM, with multiple voltage configurations available for different applications.

Generator Set

Open Type Model GPP900D6
Silent Type Model GPP900S6
Frequency 60Hz
Phase & Wires 3 Phase, 4 Wires
Power Factor 0.8
Prime Power 720kW/900kVA
Standby Power 800kW/1000kVA
Rated Voltage 120/208V; 127/220V; 220/380V; 254/440V
Rated Speed 1800 RPM
Fuel Tank Capacity 1000L

Diesel Engine

Engine Model Perkins 4006-23TAG4
Cylinder Number 6
Cylinder Arrangement Vertical In-line
Engine Type 4-Cycle Diesel
Aspiration System Turbocharged, Air-to-Air Charge Cooled
Cooling Method Water Cooled
Governor Type Electronic
Bore x Stroke 160 x 190 mm
Compression Ratio 13.6:1
Rated Speed 1800 RPM
Displacement 22.921L
Rated Power 761kW @ 1800RPM
Standby Power 842kW @ 1800RPM
Fuel System Direct Injection
Oil Capacity 113.4L
Coolant Capacity 105L
Electric Starting System DC 24V
Battery Charging Alternator 55A

Fuel Consumption

100% Prime Load 200L/H
75% Prime Load 147L/H
50% Prime Load 129L/H
25% Prime Load -
100% Standby Load 233L/H

Alternator

Number of Phase 3
Rated Power 733kW/916kVA
Frequency 60Hz
Power Factor 0.8
Poles 4
Temperature Rise 125K
Terminals 6/12
Insulation Class H Class
Ambient Temperature 40℃
IP Rating IP23
Excitation System Self-Excited
Bearing Single Bearing
Coating Vacuum Impregnation
Voltage Regulator A.V.R
Coupling Flexible Disc

Control Panel

○ Emergency stop button ○ Main circuit breaker
○ Float battery charger ○ Manual/Auto start control panel
○ Fuel level meter ○ Controller power switch
○ Alarm buzzer

SOUND ATTENUATED ENCLOSURE

The GPP900S6 silent type generator set is equipped with a sound-attenuated enclosure designed to reduce operating noise and provide reliable protection for outdoor applications.

○ Sound-attenuated enclosure for reduced noise levels
○ Weatherproof design for outdoor installation
○ Internal exhaust silencer for effective noise reduction
○ Corrosion-resistant construction for long-term outdoor use
○ Service access doors for convenient maintenance
○ Suitable for commercial, industrial and standby power applications

Options

○ ATS (Automatic Transfer Switch)
○ 20GP Containerized Enclosure
○ Remote Monitoring System
○ Water-Jacket Heater
○ Synchronization System
○ AREP Excitation System
○ PMG Excitation System

Applications

○ Commercial and office buildings
○ Industrial facilities
○ Construction and job sites
○ Agricultural and rural facilities
○ Telecommunication and remote sites
○ Emergency and standby power systems

Why Choose GENLITEC POWER

GENLITEC POWER diesel generator sets are designed to provide dependable power, practical configuration and reliable performance for a wide range of applications.

○ Perkins 4006-23TAG4 turbocharged and air-to-air charge cooled diesel engine for reliable and efficient power generation
○ Prime and standby power configurations for different operating requirements
○ Multiple voltage configurations available
○ Open and silent type configurations available
○ Suitable for commercial, industrial and backup power applications
○ Factory-direct supply with customized generator set solutions

For more information, please visit the GENLITEC POWER® Why Choose GENLITEC POWER page.

Warranty

GENLITEC POWER provides a standard warranty of 12 months or 1000 working hours, whichever comes first. For details, please refer to the GENLITEC POWER® Warranty Policy.

FAQ

Q: What is the rated power of the GPP900D6 / GPP900S6 generator set?
A: The generator set provides 720kW/900kVA prime power and 800kW/1000kVA standby power.
Q: Which diesel engine is used in the GPP900D6 / GPP900S6?
A: The generator set is powered by a Perkins 4006-23TAG4 6-cylinder, 22.921L turbocharged and air-to-air charge cooled diesel engine with electronic governing.
Q: What voltage configurations are available?
A: The available rated voltage configurations are 120/208V, 127/220V, 220/380V and 254/440V.
Q: What is the difference between the open and silent type generator sets?
A: The GPP900D6 is the open type model, while the GPP900S6 is equipped with a sound-attenuated enclosure for applications where lower noise levels and weather protection are required.
Q: What is the frequency and rated speed of the generator set?
A: The generator set operates at 60Hz with a rated speed of 1800 RPM.
Q: Can remote monitoring and a water-jacket heater be supplied?
A: Yes. Remote Monitoring System and Water-Jacket Heater are available as optional equipment.
Q: What is the warranty period for the GPP900D6 / GPP900S6?
A: GENLITEC POWER provides a standard warranty of 12 months or 1000 working hours, whichever comes first.