?> 50Hz 1200kW 1500kVA Perkins 4012-46TAG2A Diesel Generator

50Hz 1200kW 1500kVA Diesel Generator with Perkins 4012-46TAG2A Engine

50Hz 1200kW 1500kVA Diesel Generator with Perkins 4012-46TAG2A Engine - Image 1
  • 50Hz 1200kW 1500kVA Diesel Generator with Perkins 4012-46TAG2A Engine - Image 1
  • 50Hz 1200kW 1500kVA Diesel Generator with Perkins 4012-46TAG2A Engine - Image 2

Short Description

GENLITEC GPP1500D5 / GPP1500S5 diesel generator set powered by Perkins 4012-46TAG2A, with prime power 1200kW/1500kVA, standby power 1320kW/1650kVA.

  • ModelGPP1500S5
  • Prime Power (PRP)1200kW/1500kVA
  • Standby Power (ESP)1320kW/1650kVA
  • Engine4012-46TAG2A
  • Fuel consumption (100%)310L/H
Share

Product Details

Product Tags

50Hz 1200KW 1500KVA Diesel Generator with Perkins 4012-46TAG2A Diesel Engine

Introduction

The GENLITEC POWER GPP1500D5 / GPP1500S5 is a 1500 kVA diesel generator set designed for reliable prime, standby and backup power applications. With a rated output of 1200KW/1500KVA prime power and 1320KW/1650KVA standby power, this 50Hz diesel generator provides dependable three-phase power for commercial, industrial, construction, agricultural, telecommunications, data center and other demanding applications.

Powered by a Perkins 4012-46TAG2A turbocharged and air-to-air charge cooled diesel engine, the GPP1500D5 / GPP1500S5 combines a 12-cylinder 45.842L engine with electronic governing, direct injection and high power density. The generator set is available in an open type configuration and a silent type configuration. The GPP1500S5 is supplied as standard with a 40HQ containerized canopy for enhanced noise attenuation, weather protection and convenient transportation. A 2000L fuel tank is provided, while optional ATS panel, synchronization system, remote monitoring system and other accessories are available for different project requirements.

Generator Set

Open Type Model GPP1500D5
Silent Type Model GPP1500S5
Phase & Wires 3 Phase, 4 Wires
Power Factor 0.8
Frequency 50Hz
Prime Power 1200KW/1500KVA
Standby Power 1320KW/1650KVA
Rated Voltage 220/380V, 230/400V, 240/415V
Fuel Tank Capacity 2000L

Diesel Engine

Engine Model 4012-46TAG2A
Cylinder Number 12-V
Aspiration System Turbocharged and air to air charge cooled
Cooling Method Water Cooled with Radiator
Governor Type Electronic
Combustion System Direct Injection
Bore x Stroke 160 x 190 mm
Rated Speed 1500 RPM
Displacement 45.842L
Rated Power 1331KW
Standby Power 1459KW
Coolant Capacity 207L
Oil Capacity 177L
Electric Starting System DC 24V

Fuel Consumption

110% Prime Load 341L/H
100% Prime Load 310L/H
75% Prime Load 234L/H
50% Prime Load 157L/H

Alternator

Number of Phase 3
Rated Power 1200KW/1500KVA
Frequency 50Hz
Power Factor 0.8
Poles 4
Temperature Rise 125K
Terminals 12
Insulation Class H
Ambient Temperature 40℃
IP Rating IP23
Excitation System Self-Excited
Bearing Single Bearing
Coating Vacuum Impregnation
Voltage Regulator A.V.R
Coupling Flexible Disc

Control Panel

○ Emergency stop button ○ Main circuit breaker
○ Float battery charger ○ Manual/Auto start control panel
○ Fuel level meter ○ Controller power switch
○ Alarm buzzer

Sound Attenuated Enclosure

○ GPP1500S5 silent type generator set is supplied as standard with a 40HQ containerized canopy

○ Weatherproof containerized canopy with integrated sound attenuation and exhaust silencer

○ Suitable for outdoor installation and international transportation

○ 40HQ containerized design provides convenient transportation and equipment protection

Options

○ ATS for automatic start and stop when utility power fails or returns

○ Synchronization System

○ Remote monitoring system

○ Water-Jacket Heater

○ Other Heaters

Applications

The GENLITEC POWER 1200KW/1500KVA diesel generator set is suitable for a wide range of prime, standby and backup power applications, including:

○ Commercial and office buildings

○ Industrial facilities

○ Construction and job sites

○ Agricultural and rural facilities

○ Telecommunication and remote sites

○ Data centers and critical infrastructure

○ Emergency and standby power systems

Why Choose GENLITEC POWER

GENLITEC POWER GPP1500D5 / GPP1500S5 diesel generator sets combine a Perkins 4012-46TAG2A engine with a high-power generator set configuration for dependable prime and standby power.

○ Perkins 4012-46TAG2A diesel engine for reliable high-power generation

○ 1200KW/1500KVA prime power and 1320KW/1650KVA standby power

○ 45.842L twelve-cylinder engine with turbocharged and air-to-air charge cooled induction

○ 1200KW/1500KVA alternator for high-power generator applications

○ 2000L fuel tank for extended operating time

○ GPP1500S5 silent type supplied as standard with a 40HQ containerized canopy

○ Multiple voltage configurations available

○ Electronic engine governing for precise engine speed and performance management

○ Suitable for commercial, industrial, data center and backup power applications

○ Factory-direct supply with customized generator set solutions

For more information, please visit the GENLITEC POWER® Why Choose GENLITEC POWER page.

Warranty

GENLITEC POWER provides a standard warranty of 12 months or 1000 working hours, whichever comes first. For details, please refer to the GENLITEC POWER® Warranty Policy.

FAQ

Q: What is the rated power of the GPP1500D5 / GPP1500S5 generator set?
A: The generator set provides 1200KW/1500KVA prime power and 1320KW/1650KVA standby power at 50Hz.
Q: Which diesel engine is used in the GPP1500D5 / GPP1500S5?
A: The generator set is powered by a Perkins 4012-46TAG2A twelve-cylinder, 45.842L turbocharged and air-to-air charge cooled diesel engine with electronic governing and direct injection.
Q: What voltage configurations are available?
A: The available rated voltage configurations are 220/380V, 230/400V and 240/415V.
Q: What is the difference between the open and silent type generator sets?
A: The GPP1500D5 is the open type model, while the GPP1500S5 is the silent type model supplied as standard with a 40HQ containerized canopy for sound attenuation, weather protection and convenient transportation.
Q: What is the fuel consumption of the GPP1500D5 / GPP1500S5?
A: The fuel consumption is approximately 341 L/H at 110% prime load, 310 L/H at 100% prime load, 234 L/H at 75% prime load and 157 L/H at 50% prime load.
Q: What is the fuel tank capacity?
A: The standard fuel tank capacity is 2000L, providing extended operating time for high-power applications.
Q: What is the frequency and rated speed of the generator set?
A: The generator set operates at 50Hz with a rated engine speed of 1500 RPM.
Q: How many cylinders does the Perkins 4012-46TAG2A engine have?
A: The Perkins 4012-46TAG2A is a 12-cylinder V-type diesel engine with a 45.842L displacement.
Q: What are the bore and stroke of the Perkins 4012-46TAG2A engine?
A: The engine has a bore of 160 mm and a stroke of 190 mm.
Q: What are the engine oil and coolant capacities?
A: The Perkins 4012-46TAG2A has an oil capacity of approximately 177L and a coolant capacity of approximately 207L.
Q: What is the warranty period for the GPP1500D5 / GPP1500S5?
A: GENLITEC POWER provides a standard warranty of 12 months or 1000 working hours, whichever comes first.

  • Previous: 60Hz 1000kW 1250kVA Diesel Generator with Perkins 4012-46TWG2A Engine
  • Next: 50Hz 150kW 188kVA Diesel Generator with SDEC SC7H250D2 Engine

  • Related Products